ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunneling Applications

Product Details

High quality ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunneling Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
TBM Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: TENAX HTT, Reeling Cable, ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunnel

High Conductivity:Optimal Power Transmission EfficiencyRobust Durability:Exceptional Resilience In Tunnels
Shield Coverage:100%Low Smoke Emission:LSZH Insulation Minimizes Smoke
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:Russian Federation Fire Certificate (GOST)Model Number:TENAX HTT Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Jacket Color:BlackUrban Development:Supports City Infrastructure
Corrosion Resistance:Endures Tunnel EnvironmentsUv Resistant:Withstands Sunlight Exposure
Rail Tunneling:Essential For Rail ProjectsLong Lifespan:Ensures Enduring Durability
Insulation Material:PolyethyleneFlexibility:Easy Adaptation To Tunnel Contours
Tunnel Construction:Tailored For Tunnel ProjectsMining Innovation:Adapts To Evolving Technology
Attribute:DetailsBrand:ECKABEL TENAX-HTT
Type Designation:(N)TSCGEWOEUVoltage Rating:6/10 kV
Parameter:ValueRated Voltage:6/10 kV
Maximum AC Operating Voltage:6.9/12 kVMaximum DC Operating Voltage:9/18 kV
AC Test Voltage:17 kVCharacteristic:Detail
Material:Finely stranded copper (Class 5)Compliance:DIN VDE 0295, IEC 60228
Max Conductor Temperature:90°CShort Circuit Temperature:250°C
Layer:Material/CompoundConductor:Tinned annealed copper wires
Insulation:Specialized rubber (3GI3)Inner Sheath:Rubber compound (GM1B)
Reinforcement:Polyester anti-torsion braidOuter Sheath:Robust rubber compound (5GM5), red
Condition:Temperature RangeFixed Installation:-40°C to +80°C
Fully Flexible Operation:-25°C to +60°CMax Tensile Load:15 N/mm²
Torsional Stress:100°/mMax Travel Speed:30 m/min
Resistance Type:StandardFire Resistance:EN 60332-1-2, IEC 60332-1-2
Oil Resistance:EN 60811-404, IEC 60811-404Aspect:Recommendation
Bending Radii:Follow DIN VDE 0298 part 3Cable Routing:Use proper supports to prevent sagging
Inspection:Regularly check for mechanical damageOperational Limits:Maintain temperature and mechanical load limits

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunneling Applications

The ECKABEL TENAX HTT 10kV is a state-of-the-art solution for underground electrical systems in the most demanding environments. This medium-voltage reeling cable is meticulously designed to endure high mechanical stresses, harsh conditions, and continuous operational movement, making it ideal for mining and tunneling applications.

It is fully certified and compliant with rigorous international standards, including the Russian Federation Fire Certificate (GOST).

Whether it’s powering a tunnel boring machine (TBM) or connecting high-voltage transformers in hazardous environments, this cable brings reliability, safety, and durability to underground operations.


Technical Overview

2.1 Product Specification

Attribute Details
Brand ECKABEL TENAX-HTT
Type Designation (N)TSCGEWOEU
Voltage Rating 6/10 kV
Certification Russian Federation Fire Certificate (GOST)

2.2 Electrical Characteristics

Parameter Value
Rated Voltage 6/10 kV
Maximum AC Operating Voltage 6.9/12 kV
Maximum DC Operating Voltage 9/18 kV
AC Test Voltage 17 kV

2.3 Conductor Design

Characteristic Detail
Material Finely stranded copper (Class 5)
Compliance DIN VDE 0295, IEC 60228
Max Conductor Temperature 90°C
Short Circuit Temperature 250°C

ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunneling Applications 1

 

Key Design Features

3.1 Structural Composition

This cable features a robust construction that ensures both flexibility and resilience.

Layer Material/Compound
Conductor Tinned annealed copper wires
Insulation Specialized rubber (3GI3)
Inner Sheath Rubber compound (GM1B)
Reinforcement Polyester anti-torsion braid
Outer Sheath Robust rubber compound (5GM5), red

3.2 Performance Capabilities

Thermal Performance

Condition Temperature Range
Fixed Installation -40°C to +80°C
Fully Flexible Operation -25°C to +60°C

Mechanical Performance

Parameter Value
Max Tensile Load 15 N/mm²
Torsional Stress 100°/m
Max Travel Speed 30 m/min

3.3 Environmental Resistance

Resistance Type Standard
Fire Resistance EN 60332-1-2, IEC 60332-1-2
Oil Resistance EN 60811-404, IEC 60811-404

Specialized Application Scenarios

4.1 Primary Use Cases

  • Powering tunnel boring machines (TBMs)
  • Connecting high-voltage transformers in underground operations
  • Electrical connections for mining equipment in hazardous zones

4.2 Unique Advantages

  • Exceptional flexibility, ideal for continuous movement
  • Designed for slow reeling operations, reducing wear and tear
  • Enhanced protection against mechanical, thermal, and environmental stresses

ECKABEL TENAX HTT 10kV: Advanced Medium Voltage Reeling Cable for Extreme Tunneling Applications 2

 

Installation and Operational Considerations

5.1 Recommended Practices

Aspect Recommendation
Bending Radii Follow DIN VDE 0298 part 3
Cable Routing Use proper supports to prevent sagging
Inspection Regularly check for mechanical damage
Operational Limits Maintain temperature and mechanical load limits

5.2 Potential Technical Challenges

Voltage Drop Management: Prolonged cable runs may lead to voltage drops, requiring proper cable sizing and planning.

Thermal Expansion: Temperature variations can cause expansion; ensure adequate slack during installation.

Mechanical Stress: Continuous movement demands robust cable handling practices to prevent damage.


Compliance and Standards

This cable is fully compliant with DIN VDE 0250-813, ensuring reliability in underground operations. Its fire resistance and oil resistance meet stringent international standards, making it a safe choice for hazardous environments.


Conclusion

The ECKABEL TENAX HTT 10kV sets a new benchmark for medium-voltage reeling cables used in tunneling and mining applications. With its advanced engineering, robust materials, and compliance with international standards, it offers unmatched performance in extreme conditions.

Customers can rely on this cable for operational efficiency, safety, and longevity.


Technical Support and Consultation

ECKABEL offers comprehensive technical documentation, including installation guides and specifications. Customers can also consult with technical experts for tailored solutions. Additionally, ECKABEL provides customizable options to meet specific project needs.


Disclaimer: For best results, consult with ECKABEL experts before installation to ensure compliance with specific project requirements.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.