ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL PROTOLON GGSG 1.8/3KV: The Robust DC Track Feeder Cable for Demanding Railway Applications

Product Details

High quality ECKABEL PROTOLON GGSG 1.8/3KV: The Robust DC Track Feeder Cable for Demanding Railway Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: PROTOLON GGSG 1 8/3KV, ECKABEL PROTOLON GGSG 1.8/3KV: The Robust DC Track Feeder Cable for Demanding Ra, Up to 90°C Temperature Rating

Temperature Rating:Up to 90°COptimal Cable Management:Facilitates Efficient Cable Organization
High Mechanical Strength:Exhibits High Mechanical StrengthRobust Durability:Exceptional Resilience In Tunnels
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:PROTOLON GGSG 1.8/3KV Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Temperature Rating:Up To 90°CFlexible:Yes
Uv Resistant:Withstands Sunlight ExposureRail Tunneling:Essential For Rail Projects
Outer Jacket:PURAvailable Lengths:Custom Lengths Available
Cable Type:Low Smoke Zero HalogenLow Toxicity:Minimizes The Release Of Toxic Gases
Impact Resistant:Resistant To Damage From ImpactsSpecification:Details
Conductor Material:Copper, finely stranded (Class 5), per DIN EN 60228 / IEC 60228.Insulation:EPR rubber for core insulation.
Inner Sheath Material:Chlorinated Polyethylene (CM/CPE).Screen:Copper wire screen (Class 5) for EMC shielding .
Second Insulation:EPR rubber for additional mechanical protection.Outer Sheath:Chlorinated Polyethylene (CM/CPE), providing double-layered protection.
Voltage Rating:U0/U (Um): 1.8/3 (3.6) kV DC.Test Voltage:6 kV AC.
Temperature Ratings:- Maximum conductor temperature : 90°C.Standard:Purpose
DIN VDE 0250-813:Governs cables for direct current traction systems.DIN EN 60228 / IEC 60228:Sets the standards for conductors of insulated cables.
DIN EN 50363-1 & 2-1:Specifies requirements for insulating, sheathing, and covering materials for low-voltage cables.IEC/EN 60811-404:Defines test methods for mineral oil immersion resistance in sheaths.
Temperature Rating:Up to 90\u00b0C

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL PROTOLON GGSG 1.8/3KV: The Robust DC Track Feeder Cable for Demanding Railway Applications


Railway systems are critical infrastructure, and their reliability depends heavily on the performance of power supply systems. The ECKABEL PROTOLON GGSG 1.8/3KV is a specialized cable designed for DC power supply, particularly in track feeder systems used by rail networks like S-Bahn Berlin and Hamburg.

This cable offers robust construction, flame retardance, and oil resistance, ensuring reliability even in harsh conditions.

In this article, we'll explore the technical specifications, challenges, and benefits of using the ECKABEL PROTOLON GGSG cable in railway applications.

We'll also provide practical tips for installation and maintenance to help engineers and contractors maximize its performance.


Key Features and Benefits

  • Robust Construction: Designed to withstand difficult laying conditions, vibrations, and harsh environmental factors.
  • Flame Retardant and Oil Resistant: Enhances safety and durability in demanding railway environments.
  • Compliance with Railway Standards: Meets the stringent System Requirements for Track Feeder Cables by DB Netz AG.
  • Wide Installation Flexibility: Suitable for dry, damp, wet environments, pipes, ducts, direct burial, and even areas with small bending radii.

Who Should Read This Article?

This guide is tailored for:

  • Railway Infrastructure Engineers
  • Electrical Contractors
  • Maintenance Personnel working with DC traction power systems

 

Technical Specifications

Here’s a detailed breakdown of the ECKABEL PROTOLON GGSG 1.8/3KV’s specifications:

Specification Details
Conductor Material Copper, finely stranded (Class 5), per DIN EN 60228 / IEC 60228.
Insulation EPR rubber for core insulation.
Inner Sheath Material Chlorinated Polyethylene (CM/CPE).
Screen Copper wire screen (Class 5) for EMC shielding.
Second Insulation EPR rubber for additional mechanical protection.
Outer Sheath Chlorinated Polyethylene (CM/CPE), providing double-layered protection.
Voltage Rating U0/U (Um): 1.8/3 (3.6) kV DC.
Test Voltage 6 kV AC.
Temperature Ratings - Maximum conductor temperature: 90°C. 

 

Flame Retardance - Complies with EN/IEC 60332-1-2


Oil Resistance - Meets IEC/EN 60811-404 standards


Tensile Strength - 15 N/mm² (4500 N)


Bending Radius - Fixed installations: 6 x D (250mm). Free-moving: 10 x D (421mm)


CPR Reaction to Fire - Euroclass Eca


Standards and Compliance

Standards play a crucial role in ensuring the reliability and safety of railway infrastructure. The ECKABEL PROTOLON GGSG 1.8/3KV is manufactured in adherence to the following:

Standard Purpose
DIN VDE 0250-813 Governs cables for direct current traction systems.
DIN EN 60228 / IEC 60228 Sets the standards for conductors of insulated cables.
DIN EN 50363-1 & 2-1 Specifies requirements for insulating, sheathing, and covering materials for low-voltage cables.
IEC/EN 60811-404 Defines test methods for mineral oil immersion resistance in sheaths.

 

Compliance with DB Netz AG

The System Requirements for Track Feeder Cables (1.8/3 kV) from DB Netz AG are fully met, ensuring compatibility with German railway systems.


Challenges in DC Track Feeder Applications

Railway environments present unique challenges. Here’s how ECKABEL PROTOLON GGSG addresses them:

1. Harsh Environmental Conditions

  • Problem: Exposure to moisture, temperature fluctuations, and chemicals can degrade cables.
  • Solution: Double sheathing with CM/CPE ensures excellent protection against environmental factors.

2. Mechanical Stress

  • Problem: Vibrations and bending stress can damage standard cables.
  • Solution: Class 5 finely stranded copper conductors and robust sheaths resist wear and tear.

3. Electromagnetic Interference (EMI)

  • Problem: EMI can disrupt signaling systems.
  • Solution: The copper wire screen provides effective EMC shielding.

4. Difficult Laying Conditions

  • Problem: Installation in pipes, ducts, or direct burial sites can strain cables.
  • Solution: The cable’s flexibility and small bending radius enable smooth installation in tight spaces.

5. Fire Safety

  • Problem: Fires in railway systems can be catastrophic.
  • Solution: Flame retardant properties per EN/IEC 60332-1-2 enhance safety.

Installation and Maintenance Best Practices

Proper handling and maintenance are vital for maximizing the cable’s lifespan.

Installation Tips

Handle with Care: Avoid kinks or excessive bending.

Follow Bending Radius Guidelines: Ensure the minimum bending radius is observed:

Fixed installations: 6 x D.

Free-moving installations: 10 x D.

Use Standardized Connections: Compatible with all muffles, sleeves, and joints.

Check the Environment: Ensure the site meets the cable’s temperature and moisture tolerances.

Maintenance Tips

Regular Inspections: Look for wear, abrasion, or chemical damage.

Monitor Connections: Ensure all terminations are secure and properly sealed.

Plan for Replacement: Proactively replace cables showing significant degradation.


Advantages of Materials and Manufacturing Processes

Superior Sheathing Materials:

The CM/CPE sheaths are engineered for chemical resistance, flexibility, and mechanical durability.

Advanced Manufacturing Techniques:

Use of Class 5 finely stranded copper improves conductivity and mechanical resilience.

Rigorous testing ensures compliance with international standards.

Optimized for Performance:

The dual-layer insulation and robust screening guarantee reliable performance even under extreme conditions.


Conclusion

The ECKABEL PROTOLON GGSG 1.8/3KV is an indispensable component for DC track feeder systems, offering unparalleled reliability, safety, and compliance with stringent railway standards.

Why Choose ECKABEL PROTOLON GGSG?

Flame Retardant, Oil Resistant, and Durable.

Complies with DB Netz AG requirements and DIN standards.

Designed to perform in harsh conditions and difficult installations.

Whether you're an engineer designing railway infrastructure or a contractor installing DC feeder systems, this cable is the robust, reliable, and standards-compliant solution you need.

For inquiries and custom solutions, contact ECKABEL Cable today!

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat