ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

Product Details

High quality ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: AJ-2YOF 2YDB2Y H95, ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for , Reliable Power Transmission Underground Power

Underground Power:Reliable Power TransmissionFlame Resistance:Superior Fire Safety
Voltage Rating:300/500VCertifications:CE, RoHS, UL
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:s","CE, RoHS, UL"]],"company_name":null,"picurl_c":"\/photo\/pc170939347-ECKABEL_aj_2yof_l_2ydb2y_h95_railway_signalling_cable_reliable_performance_for_advanced_railway_applications.jpg","Model Number:AJ-2YOF(L)2YDB2Y H95 Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Cable Length:1000mConductor Material:Copper
Cable Type:Low Smoke Zero HalogenUrban Expansion:Facilitates City Growth
Halogen Content:ZeroImpact Resistant:Resistant To Damage From Impacts
Flexibility:Easy Adaptation To Tunnel ContoursInsulation Material:LSZH
Outer Jacket:PVC / PURShielding:Yes
Feature:DetailsMaterial:Copper
Stranding Pattern:n x 1 x 1.4 mm or 1.8 mmConductor Resistance:≤ 11.9 Ω/km (1.4 mm), ≤ 7.2 Ω/km (1.8 mm)
Component:Material/DetailsCore Insulation:Polyethylene (PE)
Longitudinal Water Blocking:YesLaminated Sheath:Copolymer-coated aluminum tape (0.15 mm)
Inner Sheath:Polyethylene (PE)Screen Construction:Copper wire screen for inductive shielding
Armouring:Galvanized steel tapeMaterial:Polyethylene (PE)
Environmental Suitability:Direct burial and submersionProperty:Value
Nominal Voltage (U/U0):600V/420VTest Voltage:2.5 kV (Core/Core and Core/Screen)
Insulation Resistance:≥ 1500 MΩ·kmCapacitance:≤ 95 nF/km (≤ 105 nF/km for single core)
Condition:SpecificationOperating Temperature:-40°C to +60°C
Laying Temperature:-10°C to +60°CBending Radius:≥ 7.5–10 x outer cable diameter
Step:Best PracticeTrenching:Use a trench depth of at least 600 mm to avoid damage.
Bedding Material:Lay the cable on a sand bed or fine soil for stability.Backfilling:Carefully backfill with soft material to prevent damage.
Waterproofing:Ensure all terminations are sealed against water ingress.Laying Technique:Use specialized tools to minimize stress on the cable.
Action:FrequencyElectrical Testing:Annually, to ensure insulation and capacitance values.
Route Inspection:Every 6 months, to check for physical damage or hazards.

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications

The ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable stands as a testament to innovation and reliability in railway signaling systems.

Designed for use in light signal operations, point machines, and similar applications, this cable delivers outstanding performance even in challenging environments.

With enhanced mutual capacitance for long-distance transmission, robust mechanical protection, and superior induction shielding, this cable is the perfect choice for railway infrastructure along electrified tracks.


Key Features and Benefits

Optimized for Long-Distance Signaling

Improved mutual capacitance ensures clear signal transmission over extended distances, reducing the need for signal repeaters.

Enhanced Induction Protection


A copper wire screen shields against inductive interference caused by electrified tracks and nearby high-voltage systems.

Robust Mechanical Durability


Steel tape armouring safeguards the cable from physical damage, particularly in direct burial applications.

Water-Resistant Design


Equipped with longitudinal water blocking, the cable is suitable for direct burial and submersion, offering longevity in diverse environmental conditions.

Compliance with Deutsche Bahn Standards


Meeting PH 416.0114 v.2.1 specifications ensures seamless integration into Deutsche Bahn systems, guaranteeing quality and safety.


Technical Specifications

1. Conductor Characteristics

Feature Details
Material Copper
Stranding Pattern n x 1 x 1.4 mm or 1.8 mm
Conductor Resistance ≤ 11.9 Ω/km (1.4 mm), ≤ 7.2 Ω/km (1.8 mm)

2. Insulation and Construction

Component Material/Details
Core Insulation Polyethylene (PE)
Longitudinal Water Blocking Yes
Laminated Sheath Copolymer-coated aluminum tape (0.15 mm)
Inner Sheath Polyethylene (PE)
Screen Construction Copper wire screen for inductive shielding
Armouring Galvanized steel tape

3. Outer Sheath and Protection

Feature Details
Material Polyethylene (PE)
Environmental Suitability Direct burial and submersion

4. Electrical Characteristics

Property Value
Nominal Voltage (U/U0) 600V/420V
Test Voltage 2.5 kV (Core/Core and Core/Screen)
Insulation Resistance ≥ 1500 MΩ·km
Capacitance ≤ 95 nF/km (≤ 105 nF/km for single core)

5. Environmental Conditions

Condition Specification
Operating Temperature -40°C to +60°C
Laying Temperature -10°C to +60°C
Bending Radius ≥ 7.5–10 x outer cable diameter

ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications 1

 

Standards and Compliance

The ECKABEL AJ-2YOF(L)2YDB2Y H95 cable is meticulously crafted to comply with Deutsche Bahn AG PH 416.0114 v.2.1, ensuring top-tier reliability and safety for critical railway signaling applications. Adherence to these rigorous standards guarantees seamless operation in even the most demanding scenarios.


Solving Common Challenges in Railway Signaling

1. Signal Attenuation Over Long Distances

Problem: Signal degradation reduces efficiency and reliability over extended distances.


Solution: The cable's improved mutual capacitance enables consistent and clear signal transmission, ensuring high performance in long-distance applications.


2. Inductive Interference

Problem: Electrified tracks often generate electromagnetic interference that disrupts signaling.


Solution: The copper wire screen offers effective shielding, minimizing interference and ensuring uninterrupted operations.


3. Mechanical Damage

Problem: Direct burial exposes cables to harsh environmental conditions, including rocks and shifting soil.


Solution: Steel tape armouring provides exceptional mechanical protection, ensuring durability and longevity.


4. Water Ingress

Problem: Water can compromise cable performance and longevity.


Solution: The longitudinal water blocking design prevents water penetration, making the cable reliable even in submerged conditions.


ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable: Reliable Performance for Advanced Railway Applications 2

 

Installation and Maintenance Best Practices

1. Direct Burial Installation

Step Best Practice
Trenching Use a trench depth of at least 600 mm to avoid damage.
Bedding Material Lay the cable on a sand bed or fine soil for stability.
Backfilling Carefully backfill with soft material to prevent damage.

2. Submersion Installation

Step Best Practice
Waterproofing Ensure all terminations are sealed against water ingress.
Laying Technique Use specialized tools to minimize stress on the cable.

3. Maintenance and Inspection

Action Frequency
Electrical Testing Annually, to ensure insulation and capacitance values.
Route Inspection Every 6 months, to check for physical damage or hazards.

Why Choose ECKABEL AJ-2YOF(L)2YDB2Y H95?

Reliability in Harsh Conditions


From humid submersion to dry burial, this cable performs consistently across environments.

Industry-Leading Compliance


Designed to meet Deutsche Bahn standards, ensuring seamless integration and reliability.

Cost Efficiency


Long-lasting construction and fewer maintenance needs lower operational costs over time.

 

 

The ECKABEL AJ-2YOF(L)2YDB2Y H95 Railway Signalling Cable is the ultimate solution for reliable, long-distance signal transmission in demanding railway environments.

With features like enhanced mutual capacitance, inductive interference protection, and robust armouring, it offers unparalleled performance for direct burial and submersion applications.

By following the provided installation and maintenance guidelines, you can ensure optimal functionality and longevity for your railway signaling systems.

Choose ECKABEL for cables that meet the highest standards and deliver unmatched performance.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat