ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Communication Solution for Railway Networks

Product Details

High quality ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Communication Solution for Railway Networks from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: A-02YSF 2Y, ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Commu, Facilitates Efficient Cable Organization Optimal Cable Management

Optimal Cable Management:Facilitates Efficient Cable OrganizationSmoke Emission:Low
Operating Temperature:-20℃ to +70℃Oil Resistant:Yes
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:A-02YSF(L)2Y Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Operating Temperature:-20℃ To +70℃Shielding:Yes
Outer Jacket:PURChemical Resistant:Resists Damage From Industrial Chemicals
Halogen Free:YesApplication:Indoor/Outdoor
Waterproof:YesFire Safety:Complies With Fire Safety Standards
Insulation Material:Low Smoke Zero HalogenProperty:Specification
Conductor Material:CopperConductor Diameter:0.8 mm
Feature:SpecificationCore Insulation:Foam-skin PE
Longitudinal Water Blocking:YesLaminated Sheath:Copolymer-coated aluminum tape (0.15 mm)
Outer Sheath Material:Polyethylene (PE)Parameter:Specification
Loop Resistance:≤ 73.2 Ω/kmInsulation Resistance:≥ 5000 MΩ·km
Maximum Operating Capacitance:≤ 42 nF/km (100% of quads)Capacitance Unbalance (k1):≤ 2660 pF/km (100%)
Attenuation (800 Hz):≤ 0.69 dB/kmCondition:Specification
Operating Temperature:-30°C to +70°CLaying Temperature:-5°C to +50°C
Bending Radius:≥ 10 x outer cable diameter (multiple bends), ≥ 5 x outer cable diameter (final bend)Step:Best Practice
Trenching:Ensure trenches are smooth and free of sharp objects.Bedding:Lay cables on a bed of fine sand or soil to cushion.
Backfilling:Use suitable material to protect the cable.Route Marking:Use clear markers to indicate cable location.
Connectors and Termination:Use waterproof connectors to prevent water ingress.Regular Inspection:Periodically inspect for mechanical damage or wear.
Operating Temperature:-20\u2103 to +70\u2103

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations

Robust Communication Solution for Railway Networks


 

Railway stations demand highly reliable and efficient communication systems to ensure operational safety, efficiency, and uninterrupted service.

ECKABEL's A-02YSF(L)2Y telecommunication cable offers an ideal solution, specifically designed to meet the rigorous requirements of Deutsche Bahn AG TL 416.0531 V.1.0. With features like star-quad stranding, longitudinal water blocking, and a robust PE outer sheath, this cable is built to withstand harsh environmental conditions, ensuring high performance in telecommunication and data transmission.

Key Features and Benefits

  • Optimized for Railway Station Networks: Designed to enhance communication in railway environments.
  • Star-Quad Stranding: Minimizes interference and crosstalk, ensuring signal integrity.
  • Longitudinal Water Blocking: Prevents water ingress, increasing cable lifespan.
  • Robust PE Outer Sheath: Protects against mechanical damage, making it suitable for direct burial or duct installation.

This article will guide you through the cable’s technical specifications, advantages, installation best practices, and how it solves common challenges in railway telecommunication networks.


ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Communication Solution for Railway Networks 1

 

Technical Specifications

A. Conductor Characteristics

Property Specification
Conductor Material Copper
Conductor Diameter 0.8 mm

B. Insulation and Construction

Feature Specification
Core Insulation Foam-skin PE
Longitudinal Water Blocking Yes
Laminated Sheath Copolymer-coated aluminum tape (0.15 mm)
Outer Sheath Material Polyethylene (PE)

C. Electrical Characteristics

Parameter Specification
Loop Resistance ≤ 73.2 Ω/km
Insulation Resistance ≥ 5000 MΩ·km
Maximum Operating Capacitance ≤ 42 nF/km (100% of quads)
Capacitance Unbalance (k1) ≤ 2660 pF/km (100%)
Attenuation (800 Hz) ≤ 0.69 dB/km

D. Environmental and Operating Conditions

Condition Specification
Operating Temperature -30°C to +70°C
Laying Temperature -5°C to +50°C
Bending Radius ≥ 10 x outer cable diameter (multiple bends), ≥ 5 x outer cable diameter (final bend)

 

 

E. Standards Compliance

The cable complies with Deutsche Bahn AG TL 416.0531 V.1.0, ensuring that it meets strict performance and safety standards required by railway communication networks.


ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Communication Solution for Railway Networks 2

 

 

Common Challenges and How ECKABEL A-02YSF(L)2Y Solves Them

1. Signal Integrity in Noisy Environments

Railway stations are plagued with electrical noise from heavy machinery, train operations, and high-power equipment.

Solution:

  • Star-quad stranding significantly reduces crosstalk and ensures balanced signal transmission.
  • Low attenuation and capacitance unbalance parameters maintain signal clarity over long distances.

2. Protection Against Environmental Factors

Direct burial or installation in ducts exposes cables to mechanical stress, moisture, and temperature fluctuations.

Solution:

  • Longitudinal water blocking prevents water ingress, safeguarding cable integrity.
  • The PE outer sheath resists environmental wear and tear, ensuring durability.

3. Mechanical Damage During Installation

Improper installation can lead to mechanical stress, leading to potential failures.

Solution:

  • ECKABEL’s cable features a robust construction that withstands rough handling during installation.
  • The bending radius ensures flexibility, reducing the risk of internal damage.

ECKABEL A-02YSF(L)2Y Telecommunication Cable for Railway Stations - Robust Communication Solution for Railway Networks 3

 

Installation and Maintenance Best Practices

1. Trenching and Bedding for Direct Burial

Step Best Practice
Trenching Ensure trenches are smooth and free of sharp objects.
Bedding Lay cables on a bed of fine sand or soil to cushion.

2. Backfilling and Route Marking

Step Best Practice
Backfilling Use suitable material to protect the cable.
Route Marking Use clear markers to indicate cable location.

3. Termination and Connections

Step Best Practice
Connectors and Termination Use waterproof connectors to prevent water ingress.
Regular Inspection Periodically inspect for mechanical damage or wear.

 

 

Conclusion

The ECKABEL A-02YSF(L)2Y telecommunication cable is a robust solution for railway station communication networks. Designed to comply with Deutsche Bahn AG TL 416.0531 V.1.0, it offers unparalleled performance and durability in challenging environments.

Key Advantages

  • Enhanced Signal Integrity: Star-quad stranding reduces crosstalk.
  • Durability: Robust construction and water-blocking features ensure long-term reliability.
  • Compliance: Fully adheres to Deutsche Bahn standards, guaranteeing safety and compatibility.

By following best practices for installation and maintenance, this cable can provide reliable communication infrastructure for decades.


Equip your railway station with the ECKABEL A-02YSF(L)2Y cable, a solution that delivers performance, reliability, and compliance. For more information or to place an order, contact ECKABEL today!

Tags:

Low Smoke Zero Halogen Cable,

LSZH Cable,

Low Smoke Halogen Free Cable

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote