ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations

Product Details

High quality ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: AJ-02YSF 2YDB2Y, ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations, Various sizes available Available Sizes

Available Sizes:Various sizes availableFire Safety:Complies With Fire Safety Standards
Impact Resistant:Resistant To Damage From ImpactsFlame Resistant:Exhibits Excellent Resistance To Flames
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:AJ-02YSF(L)2YDB2Y Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Available Sizes:Various Sizes AvailableUnderground Power:Reliable Power Transmission
High Mechanical Strength:Exhibits High Mechanical StrengthFlame Resistance:Superior Fire Safety
Conductor Material:CopperOptimal Cable Management:Facilitates Efficient Cable Organization
Cable Type:Low Smoke Zero HalogenParameter:Value
Loop Resistance:≤ 73.2 Ω/kmInsulation Resistance:≥ 5000 MΩ·km
Capacitance Unbalance:k1 ≤ 2660 pF/km (100%)Attenuation (800 Hz):≤ 0.69 dB/km
Test Voltage:Core/Core: 500 V; Core/Screen: 2000 VOperating Temperature:-30°C to +70°C
Laying Temperature:-5°C to +50°CBending Radius:Multiple bends ≥ 10x cable diameter; Final bends ≥ 7.5x cable diameter
Challenge:Solution by ECKABEL AJ-02YSF(L)2YDB2YInductive Interference:Copper wire screen and laminated sheath mitigate interference.
Mechanical Damage (Direct Burial):Steel tape armouring protects against physical stress.Water Ingress:Longitudinal water blocking and PE sheath prevent water penetration.
Signal Integrity Over Distance:Star-quad stranding minimizes crosstalk and ensures clear transmission.Space Constraints:Flexible design enables duct or direct burial installations.

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations

Reliable Communication Solutions for Railway Networks

Railway stations are hubs of connectivity where telecommunication and data networks play a crucial role in ensuring smooth operations.

ECKABEL's AJ-02YSF(L)2YDB2Y Telecommunication Cable is purpose-built for railway environments, designed to deliver superior performance under challenging conditions.

Compliant with Deutsche Bahn AG TL 416.0531 V.1.0, this cable ensures reliability, durability, and efficiency, addressing critical challenges in railway station telecommunication systems.


 

I. Introduction

Efficient communication in railway stations depends on robust infrastructure. Cables face a range of challenges, from inductive interference caused by nearby power systems to the physical stress of direct burial installations.

The ECKABEL AJ-02YSF(L)2YDB2Y cable provides a cutting-edge solution that not only meets but exceeds these demands. This article will explore its technical features, advantages, and best practices for installation and maintenance to help users achieve optimal performance.


II. Technical Specifications

A. Conductor Characteristics

  • Material: High-quality copper conductors
  • Diameter: 0.8 mm
  • Advantage: Ensures excellent electrical conductivity and signal integrity

B. Insulation and Construction

  • Core Insulation: Foam-skin PE for low signal attenuation
  • Water Blocking: Longitudinal water-blocking design to prevent water ingress
  • Sheath: Laminated copolymer-coated aluminum tape (0.15 mm)
  • Inner Sheath: Durable Polyethylene (PE)
  • Screen Construction: Copper wire screen for strong inductive interference protection
  • Armouring: Galvanized steel tape for enhanced mechanical durability

C. Outer Sheath

  • Material: Polyethylene (PE)
  • Benefit: Superior environmental protection, suitable for direct burial and duct installation

D. Electrical Characteristics

Parameter Value
Loop Resistance ≤ 73.2 Ω/km
Insulation Resistance ≥ 5000 MΩ·km
Capacitance Unbalance k1 ≤ 2660 pF/km (100%)
Attenuation (800 Hz) ≤ 0.69 dB/km
Test Voltage Core/Core: 500 V; Core/Screen: 2000 V

E. Environmental and Mechanical Properties

Operating Temperature -30°C to +70°C
Laying Temperature -5°C to +50°C
Bending Radius Multiple bends ≥ 10x cable diameter; Final bends ≥ 7.5x cable diameter

 

ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations 1

III. Standards and Compliance

A. Importance of Standards Compliance

Compliance ensures the cable's interoperability, safety, and adherence to railway regulations. ECKABEL's cable meets the stringent requirements of Deutsche Bahn AG standards.

B. Key Standards

  • Deutsche Bahn AG TL 416.0531 V.1.0: Governs cable design, performance, and testing for railway infrastructure.

IV. Common Challenges in Railway Station Telecommunications and Solutions

Challenge Solution by ECKABEL AJ-02YSF(L)2YDB2Y
Inductive Interference Copper wire screen and laminated sheath mitigate interference.
Mechanical Damage (Direct Burial) Steel tape armouring protects against physical stress.
Water Ingress Longitudinal water blocking and PE sheath prevent water penetration.
Signal Integrity Over Distance Star-quad stranding minimizes crosstalk and ensures clear transmission.
Space Constraints Flexible design enables duct or direct burial installations.

 

V. Installation and Maintenance Best Practices

A. Direct Burial Installation

Trenching and Bedding:

Dig a trench of appropriate depth and width.

Lay the cable on a smooth sand bed to avoid sharp object damage.

Backfilling and Compaction:

Use suitable backfill material and compact it in layers for stability.

Cable Markers:

Install route markers to prevent accidental damage during future excavations.

B. Duct Installation

Duct Preparation:

Clean ducts thoroughly to remove debris.

Pulling and Lubrication:

Use appropriate lubricants to reduce friction and stress during pulling.

C. Termination and Grounding

Ensure proper grounding of the copper wire screen for optimal interference protection.

Use watertight terminations for direct burial applications.

D. Routine Maintenance

Conduct regular visual inspections and periodic electrical tests.


ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable for Railway Stations 2

 

VI. Advantages of ECKABEL AJ-02YSF(L)2YDB2Y Cable

A. Superior Materials and Manufacturing

Foam-skin PE insulation ensures excellent electrical properties.

Steel tape armouring provides robust mechanical protection.

Longitudinal water blocking and durable PE sheath prevent moisture ingress.

B. Designed for Railway Environments

Star-quad stranding and capacitance balancing minimize signal loss.

Optimized for installation in tight spaces, ducts, or direct burial applications.

C. Enhanced Performance

Outstanding attenuation and resistance values ensure signal clarity.

Withstands extreme temperatures and mechanical stress, delivering reliable performance.


VII. Conclusion

The ECKABEL AJ-02YSF(L)2YDB2Y Telecommunication Cable offers an unbeatable combination of durability, reliability, and compliance with Deutsche Bahn AG TL 416.0531 V.1.0. Designed to tackle challenges in railway station environments, this cable provides reliable performance in both direct burial and ducted installations.

Key Takeaways:

Robust materials and shielding address common challenges like interference and mechanical damage.

Best practices for installation and maintenance enhance cable longevity and efficiency.

ECKABEL's commitment to quality ensures this cable is a reliable choice for modern railway stations.

For further details, consult the Deutsche Bahn AG TL 416.0531 V.1.0 specification or contact ECKABEL Cable for tailored solutions. Invest in the best – ECKABEL AJ-02YSF(L)2YDB2Y is the ultimate choice for railway telecommunication networks!

 

Tags:

Low Smoke Zero Halogen Cable,

LSZH Cable,

Low Smoke Halogen Free Cable

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat