ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV OM S 150°C Halogen-Free Cables: Ensuring Safety and Reliability in Railway Rolli

Product Details

High quality ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV OM S 150°C Halogen-Free Cables: Ensuring Safety and Reliability in Railway Rolling Stock from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SIENOPYR 180, ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV OM S 150°C Halogen-Free Cables: En, Exhibits Excellent Resistance To Flames Flame Resistant

Flame Resistant:Exhibits Excellent Resistance To FlamesRail Tunneling:Essential For Rail Projects
Chemical Resistant:Resists Damage From Industrial ChemicalsOperating Temperature:-20℃ to +70℃
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Operating Temperature:-20℃ To +70℃Crush Resistance:≥1000N/100mm
Low Toxicity:Minimizes The Release Of Toxic GasesOptimal Cable Management:Facilitates Efficient Cable Organization
Jacket Material:LSZHType:Low Smoke Zero Halogen Cable
Low Smoke Emission:Reduces Smoke Emission During CombustionShielding:Yes
Flame Resistance:Superior Fire SafetyComponent:Material
Conductor:Tinned, finely stranded Class 5 copper (DIN EN 60228)Insulation:Cross-linked LS0H material
Screen:Tinned copper braidingOuter Sheath:Silicone rubber
Attribute:ValueRated Voltage (U0/U):3.6/6 (7.2) kV
Test Voltage:11 kVThermal Performance:150°C (normal) / 350°C (short circuit)
Bending Radius:Fixed: 6xOD, Free Moving: 10xODProperty:Value
Operating Temperature:-50°C to +150°CPermanent Tensile Strength:15 N/mm²
Standard:RelevanceDIN EN 50382-1 & 2:High-temperature cables for railway rolling stock with special fire behavior.
DIN EN 60228:Specifies conductor materials and classes for optimal electrical performance.DIN EN 50305:Comprehensive test methods for railway cable durability and safety.
DIN EN 45545:Fire protection for railway vehicles, achieving HL1, HL2, and HL3 compliance.DIN EN 61034-2:Ensures low smoke density in confined spaces like tunnels.
DIN EN 50343:Installation rules for railway cables, emphasizing proper routing and fixing.Challenge:Solution Provided by SIENOPYR (180)
Fire Risk:Halogen-free insulation ensures minimal smoke and toxic gas emission.High-Temperature Environments:Silicone sheath operates reliably up to 150°C and short-circuits up to 350°C.
Mechanical Stress:Flexible design and robust materials resist vibration and mechanical damage.Outdoor Exposure:UV and weather-resistant outer sheath for long-term performance in diverse climates.
Parameter:SpecificationVoltage Rating:3.6/6 kV
Maximum Conductor Temperature:150°CMinimum Installation Temperature:-50°C
Hazard Level Compliance:HL1, HL2, HL3Operating Temperature:-20\u2103 to +70\u2103

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV OM S 150°C Halogen-Free Cables: Ensuring Safety and Reliability in Railway Rolling Stock

Introduction: Prioritizing Fire Safety in Railway Applications

Fire safety is a top priority in modern railway systems, where passenger safety and equipment reliability depend on the use of advanced materials and cutting-edge technology.

Cables are a critical component, providing power, control, and communication connections across a range of demanding environments.

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE cables represent the pinnacle of innovation, combining halogen-free construction, superior fire performance, and exceptional high-temperature resistance.

Designed for railway rolling stock, these cables meet the stringent requirements of hazard levels HL1, HL2, and HL3 as per DIN EN 45545-1:2013.

Whether used for fixed wiring or limited flexing applications, these cables excel both indoors and outdoors, making them ideal for environments like connections between car floors and bogies, auxiliary circuits, and electric heating systems.

In this article, we will explore the technical specifications, design features, compliance with standards, and practical installation considerations for these high-performance cables, offering invaluable insights for railway engineers, manufacturers, and maintenance professionals.


 

Technical Specifications and Design Features

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE cables are engineered for extreme operating conditions. Below is a detailed breakdown of their construction and performance attributes:

Cable Construction

Component Material Function
Conductor Tinned, finely stranded Class 5 copper (DIN EN 60228) High flexibility and corrosion resistance for long-term reliability.
Insulation Cross-linked LS0H material Ensures low smoke emission and no toxic halogens during fire.
Screen Tinned copper braiding Provides EMC protection, reducing interference from external sources.
Outer Sheath Silicone rubber Exceptional resistance to high temperatures, UV radiation, and environmental factors.

 

 

Key Electrical Characteristics

Attribute Value Significance
Rated Voltage (U0/U) 3.6/6 (7.2) kV Suitable for medium-voltage auxiliary circuits in railway applications.
Test Voltage 11 kV Provides assurance of insulation integrity.
Thermal Performance 150°C (normal) / 350°C (short circuit) Ideal for high-temperature zones near braking systems or engine compartments.
Bending Radius Fixed: 6xOD, Free Moving: 10xOD Prevents damage during installation and operation.

 

 

Environmental and Mechanical Properties

Property Value Advantage
Operating Temperature -50°C to +150°C Reliable performance in extreme climates.
Permanent Tensile Strength 15 N/mm² Suitable for secure routing and installation under tension.

 

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE 3.6/6kV OM S 150°C Halogen-Free Cables: Ensuring Safety and Reliability in Railway Rolling Stock 1

 

Compliance with Industry Standards

ECKABEL SIENOPYR (180) (N)HXSGAFCHXOE cables adhere to the highest international standards, ensuring unmatched performance, reliability, and safety.

Standard Relevance
DIN EN 50382-1 & 2 High-temperature cables for railway rolling stock with special fire behavior.
DIN EN 60228 Specifies conductor materials and classes for optimal electrical performance.
DIN EN 50305 Comprehensive test methods for railway cable durability and safety.
DIN EN 45545 Fire protection for railway vehicles, achieving HL1, HL2, and HL3 compliance.
DIN EN 61034-2 Ensures low smoke density in confined spaces like tunnels.
DIN EN 50343 Installation rules for railway cables, emphasizing proper routing and fixing.

These standards highlight the cable's fire performance, ensuring it minimizes risk in critical scenarios like fires in confined tunnels or train compartments.


 

Practical Considerations and Installation Guidance

To maximize the reliability and safety of these cables, it’s crucial to follow best practices for installation and maintenance:

Installation Guidelines

Storage and Handling: Store in a cool, dry place, avoiding exposure to direct sunlight or moisture.

Bending Radius: Always adhere to the specified limits to prevent damage to insulation and screening layers.

Cable Routing: Securely fasten cables to minimize vibration and mechanical stress. Use clamps and conduits in areas with high movement.

Termination Techniques: Use compatible connectors to maintain fire safety integrity and electrical performance.

Temperature Considerations: Ensure that tie materials used for cable fixing can withstand operating temperatures.

Maintenance Tips

  • Visual Inspections: Regularly check for sheath degradation or external damage.
  • Electrical Testing: Conduct periodic insulation resistance and continuity tests.
  • Replacement Criteria: Replace cables showing excessive wear or reduced electrical performance.

Benefits of ECKABEL SIENOPYR (180) Cables

Challenge Solution Provided by SIENOPYR (180)
Fire Risk Halogen-free insulation ensures minimal smoke and toxic gas emission.
High-Temperature Environments Silicone sheath operates reliably up to 150°C and short-circuits up to 350°C.
Mechanical Stress Flexible design and robust materials resist vibration and mechanical damage.
Outdoor Exposure UV and weather-resistant outer sheath for long-term performance in diverse climates.

 

Conclusion: Choosing ECKABEL SIENOPYR (180) for Fire-Safe Railway Operations

ECKABEL SIENOPYR (180) cables stand out as a top-tier solution for railway rolling stock, offering a unique combination of fire performance, high-temperature resistance, and mechanical reliability.

Compliance with stringent standards ensures safe operation across various hazard levels, making them an indispensable choice for railway engineers and operators.

For further details, technical support, or inquiries, contact ECKABEL Cables today and experience the difference in safety and reliability.


Appendix

Technical Data Summary

Parameter Specification
Voltage Rating 3.6/6 kV
Maximum Conductor Temperature 150°C
Minimum Installation Temperature -50°C
Hazard Level Compliance HL1, HL2, HL3

Glossary

  • LS0H: Low Smoke Zero Halogen
  • DIN EN 45545: Fire protection standard for railway vehicles

This comprehensive article equips professionals with the knowledge needed to make informed decisions about ECKABEL SIENOPYR (180) cables, ensuring a safer and more efficient railway system.

Tags:

Low Smoke Zero Halogen Cable,

LSZH Cable,

Low Smoke Halogen Free Cable

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote