ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

Product Details

High quality ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SIENOPYR 180, ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cab, Optimal Power Transmission Efficiency High Conductivity

High Conductivity:Optimal Power Transmission EfficiencyTemperature Rating:-40°C to +90°C
Chemical Resistant:Resists Damage From Industrial ChemicalsBraid:With or without tinned copper
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:(N)HXSGAFHXOE 3,6/6KV Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Temperature Rating:-40°C To +90°CBraid:With Or Without Tinned Copper
Application:Indoor/OutdoorRohs Compliant:Yes
Urban Expansion:Facilitates City GrowthFlexibility:Easy Adaptation To Tunnel Contours
Installation Method:Indoor/OutdoorFlame Resistance:Superior Fire Safety
Smoke Emission:LowType:Single Mode
Conductor Size:14 AWGFlexible:Yes
Component:DescriptionConductor:Tinned, finely stranded Class 5 copper per DIN EN 60228. Ensures flexibility , corrosion resistance , and efficient electrical conductivity.
Insulation:Cross-linked Silicone Insulating Rubber (SIR) , type EI 112. Halogen-free for fire safety and minimal smoke emission.Outer Sheath:Silicone rubber. Provides UV resistance , durability in harsh environments, and thermal stability.
Shielding (optional):Tinned copper braiding for EMC protection , reducing interference in sensitive electronic systems.Characteristic:Value
Rated Voltage (U0/U):3.6/6 (7.2) kV. Suitable for traction circuits , auxiliary systems , and electric heating .Test Voltage:11 kV. Ensures insulation reliability under extreme conditions.
Maximum Conductor Temperature:150°C. Ideal for high-temperature areas near braking systems and engines.Short Circuit Temperature:350°C. Provides enhanced safety during fault conditions.
Property:SpecificationTensile Strength:≥ 15 N/mm². Ensures mechanical durability.
Bending Radius:Fixed Installation : 4xD (D≤12mm) or 5xD (D>12mm). Flexible Installation : 10xD. Restricted Movement : 8xD.Laying Temperature:-50°C minimum. Suitable for extreme cold environments .
Operating Temperature Range:-50°C to +150°C. Ideal for applications exposed to temperature fluctuations .Standard:Purpose and Relevance
DIN EN 50382:Rolling stock cables with special fire behavior .DIN EN 50305:Establishes test conditions for mechanical and electrical reliability in rolling stock cables.
DIN EN 45545:Fire protection for railway vehicles, including hazard levels HL1, HL2, and HL3 .DIN EN 61034-2:Measures smoke density , crucial for visibility during fire emergencies .
DIN EN 60228:Specifies conductor quality for durability and efficiency.DIN EN 50343:Guidelines for installation of cables in railway environments.
Aspect:RecommendationsCable Handling:Avoid exceeding the minimum bending radius during installation to prevent insulation damage.
Storage:Store in dry, UV-protected areas to maintain sheath integrity.Routing:Route cables to minimize vibration and abrasion. Use protective conduits where necessary.
Terminations:Use high-temperature-rated glands and connectors for proper sealing and electrical performance.Challenge:Solution
Extreme Temperatures:Use heat shields in areas with prolonged exposure to high temperatures (e.g., near brakes).Vibration:Secure cables with high-strength clamps to avoid mechanical wear.
Chemical Exposure:Silicone outer sheaths resist oils and greases but should be inspected regularly for damage.UV Radiation:UV-resistant sheath ensures long-term outdoor performance .
Inspection Task:FrequencyVisual Checks:Quarterly. Look for signs of abrasion, sheath degradation, or mechanical damage .
Electrical Testing:Annually. Measure insulation resistance and conductor integrity.Replacement Planning:Assess service life based on stress levels and environmental conditions.
Temperature Rating:-40\u00b0C to +90\u00b0C

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

ECKABEL SIENOPYR(180) cables are at the forefront of innovation in high-temperature power cable technology, specifically designed for railway rolling stock.

These halogen-free, single-core cables offer exceptional fire performance, withstand demanding mechanical and thermal environments, and comply with stringent industry standards.

This article provides an in-depth guide to the SIENOPYR(180) (N)HXSGAFHXOE 3.6/6KV OM 150°C cables, emphasizing their construction, practical applications, compliance with safety standards, and installation best practices.


ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance 0

 

I. Introduction: Meeting the Demands of Modern Rail Transport

The modern railway industry faces stringent safety regulations, increased power requirements, and demands for sustainability. Electrical components, particularly cables, play a vital role in ensuring the reliability and safety of these systems.

ECKABEL stands out as a leader in specialized cable solutions, offering products engineered to meet the challenges of modern rail transport. The SIENOPYR(180) cables are designed to:

  • Perform in high-temperature environments.
  • Comply with fire safety standards.
  • Provide reliability under conditions involving limited flexing or fixed wiring in rolling stock.
  • Meet the fire safety hazard levels HL1, HL2, and HL3, per DIN EN 45545-1:2013.

 

 

II. Cable Construction and Technical Specifications: Designed for Extreme Conditions

The SIENOPYR(180) cables are engineered for durability and safety. Let’s delve into their core components and technical specifications.

Key Components

Component Description
Conductor Tinned, finely stranded Class 5 copper per DIN EN 60228. Ensures flexibility, corrosion resistance, and efficient electrical conductivity.
Insulation Cross-linked Silicone Insulating Rubber (SIR), type EI 112. Halogen-free for fire safety and minimal smoke emission.
Outer Sheath Silicone rubber. Provides UV resistance, durability in harsh environments, and thermal stability.
Shielding (optional) Tinned copper braiding for EMC protection, reducing interference in sensitive electronic systems.

 

 

Electrical Characteristics

Characteristic Value
Rated Voltage (U0/U) 3.6/6 (7.2) kV. Suitable for traction circuits, auxiliary systems, and electric heating.
Test Voltage 11 kV. Ensures insulation reliability under extreme conditions.
Maximum Conductor Temperature 150°C. Ideal for high-temperature areas near braking systems and engines.
Short Circuit Temperature 350°C. Provides enhanced safety during fault conditions.

 

 

Mechanical Properties

Property Specification
Tensile Strength ≥ 15 N/mm². Ensures mechanical durability.
Bending Radius Fixed Installation: 4xD (D≤12mm) or 5xD (D>12mm).
Flexible Installation: 10xD.
Restricted Movement: 8xD.
Laying Temperature -50°C minimum. Suitable for extreme cold environments.
Operating Temperature Range -50°C to +150°C. Ideal for applications exposed to temperature fluctuations.

 

 

ECKABEL SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance 1

 

 

III. Compliance with Industry Standards: Ensuring Safety and Performance

ECKABEL SIENOPYR(180) cables are meticulously designed to meet or exceed industry standards for safety and performance.

Key Standards

Standard Purpose and Relevance
DIN EN 50382 Rolling stock cables with special fire behavior.
DIN EN 50305 Establishes test conditions for mechanical and electrical reliability in rolling stock cables.
DIN EN 45545 Fire protection for railway vehicles, including hazard levels HL1, HL2, and HL3.
DIN EN 61034-2 Measures smoke density, crucial for visibility during fire emergencies.
DIN EN 60228 Specifies conductor quality for durability and efficiency.
DIN EN 50343 Guidelines for installation of cables in railway environments.

These standards ensure:

  • Fire safety compliance for passenger and equipment protection.
  • Interoperability across different railway systems.
  • Long-lasting performance in challenging environments.

IV. Practical Considerations and Potential Challenges: Real-World Applications

Installation Best Practices

Proper installation ensures optimal performance and extends the lifespan of SIENOPYR(180) cables.

Aspect Recommendations
Cable Handling Avoid exceeding the minimum bending radius during installation to prevent insulation damage.
Storage Store in dry, UV-protected areas to maintain sheath integrity.
Routing Route cables to minimize vibration and abrasion. Use protective conduits where necessary.
Terminations Use high-temperature-rated glands and connectors for proper sealing and electrical performance.

 

Environmental Challenges

SIENOPYR(180) cables are built to endure harsh conditions, but specific precautions enhance their effectiveness:

Challenge Solution
Extreme Temperatures Use heat shields in areas with prolonged exposure to high temperatures (e.g., near brakes).
Vibration Secure cables with high-strength clamps to avoid mechanical wear.
Chemical Exposure Silicone outer sheaths resist oils and greases but should be inspected regularly for damage.
UV Radiation UV-resistant sheath ensures long-term outdoor performance.

 

 

Maintenance and Inspection

Regular inspection is key to maintaining performance and safety:

Inspection Task Frequency
Visual Checks Quarterly. Look for signs of abrasion, sheath degradation, or mechanical damage.
Electrical Testing Annually. Measure insulation resistance and conductor integrity.
Replacement Planning Assess service life based on stress levels and environmental conditions.

 

V. Conclusion: The Advantages of ECKABEL SIENOPYR(180)

ECKABEL SIENOPYR(180) cables are the optimal choice for railway rolling stock, offering:

  • Exceptional fire safety, meeting HL1, HL2, and HL3 requirements.
  • High-temperature resistance for demanding environments.
  • Compliance with industry standards, ensuring safety and reliability.
  • Durability in mechanical and thermal extremes.

Choose ECKABEL for unmatched reliability and safety in your railway applications. For more information or technical assistance, contact ECKABEL today.


This comprehensive guide equips professionals with the knowledge needed to install, maintain, and maximize the performance of SIENOPYR(180) cables.

 

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat