ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL SIENOPYR(120) (N)HXSGAFCHXOE 3,6/6KV: Halogen-Free Cables for Enhanced Fire Safety in Railway Rolling Stock

Product Details

High quality ECKABEL SIENOPYR(120) (N)HXSGAFCHXOE 3,6/6KV: Halogen-Free Cables for Enhanced Fire Safety in Railway Rolling Stock from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
LSZH Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SIENOPYR 120, ECKABEL SIENOPYR(120) (N)HXSGAFCHXOE 3,6/6KV: Halogen-Free Cables for Enhanced F, PUR Outer Jacket

Outer Jacket:PURFlame Resistant:Exhibits Excellent Resistance To Flames
Voltage Rating:300VConductor Material:Copper
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:(N)HXSGAFCHXOE 3,6/6KV Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Waterproof:YesBraid:With Or Without Tinned Copper
Chemical Resistant:Resists Damage From Industrial ChemicalsCable Length:1000m
Uv Resistant:YesHalogen Content:Zero
Smoke Emission:LowAvailable Sizes:Various Sizes Available
Component:MaterialConductor:Tinned, finely stranded Class 5 copper (IEC 60228)
Insulation:Cross-linked LS0H (Low Smoke Zero Halogen)Screen Material:Braided tinned copper
Outer Sheath:EVA (Ethylene Vinyl Acetate) rubberParameter:Value
Rated Voltage (U0/U):3.6/6 (7.2) kVTest Voltage:11 kV
Maximum Conductor Temperature:120°CShort Circuit Temperature:250°C
Property:ValueBending Radius (Fixed):6 x OD
Bending Radius (Moving):10 x ODLaying Temperature:-40°C
Tensile Strength:15 N/mm²Standard:Description
DIN EN 50264-3-1:Defines fire performance requirements for thin-wall railway rolling stock cables.DIN EN 45545:Sets fire safety requirements for railway vehicles at hazard levels HL1, HL2, HL3.
IEC 60228:Governs conductors of insulated cables, ensuring durability and reliability.DIN EN 61034-2:Measures smoke density of cables under fire conditions, vital for safe evacuation.
IEC 60332-3-24:Tests flame spread of cable bunches, ensuring reduced fire propagation.IEC 60811-404:Tests for material resistance to oils, ensuring performance under challenging conditions.
Installation Aspect:RecommendationStorage:Store in dry conditions, away from UV exposure and mechanical damage.
Handling:Avoid sharp bends exceeding bending radius limits.Routing:Secure cables to prevent vibration or abrasion, particularly in bogies.
Termination:Use compatible glands and connectors rated for 3.6/6 kV applications.Activity:Purpose
Visual Inspection:Check for wear, abrasion, and sheath damage.Electrical Testing:Verify insulation integrity and electrical performance.
Replacement Criteria:Replace cables showing significant degradation or exceeding service life.Rated Voltage:3.6/6 (7.2) kV
Max Conductor Temperature:120°CFire Standard Compliance:DIN EN 45545

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL SIENOPYR(120) (N)HXSGAFCHXOE 3,6/6KV: Halogen-Free Cables for Enhanced Fire Safety in Railway Rolling Stock

 

Target Audience: Railway engineers, rolling stock manufacturers, maintenance personnel, safety engineers, and procurement specialists.


 

I. Introduction: Prioritizing Safety in Railway Cable Systems

Modern railway systems demand superior safety, reliability, and performance. The electrical cabling in rolling stock plays a critical role in powering operations, connecting circuits, and ensuring safety during emergencies. With increasing regulatory focus on fire performance, choosing the right cable is essential.

ECKABEL SIENOPYR(120) halogen-free cables provide exceptional fire safety performance for fixed wiring and applications involving limited flexing in railway rolling stock.

These cables meet stringent standards, ensuring passenger safety, reliability, and operational efficiency. Designed for a rated voltage of 3.6/6 kV, these cables excel in harsh environments, offering excellent thermal stability and low smoke emission.


II. Cable Construction and Technical Specifications: Engineered for Safety and Performance

Cable Construction Overview

Component Material Key Benefits
Conductor Tinned, finely stranded Class 5 copper (IEC 60228) Enhanced flexibility, corrosion resistance, and efficient current carrying capacity.
Insulation Cross-linked LS0H (Low Smoke Zero Halogen) Superior fire resistance, low smoke emission, non-toxic during combustion.
Screen Material Braided tinned copper Improves electromagnetic compatibility (EMC), reduces interference.
Outer Sheath EVA (Ethylene Vinyl Acetate) rubber Flame retardancy, oil and ozone resistance, durability under vibration and abrasion.

Electrical and Thermal Characteristics

Parameter Value Explanation
Rated Voltage (U0/U) 3.6/6 (7.2) kV Suitable for medium-voltage railway power systems.
Test Voltage 11 kV Ensures insulation integrity under operational stress.
Maximum Conductor Temperature 120°C Enables operation in high-temperature environments without degradation.
Short Circuit Temperature 250°C Withstands fault conditions, minimizing fire risks.

Mechanical and Environmental Characteristics

Property Value Application Benefit
Bending Radius (Fixed) 6 x OD Prevents mechanical damage during installation.
Bending Radius (Moving) 10 x OD Maintains cable integrity in dynamic applications.
Laying Temperature -40°C Suitable for extreme cold conditions common in railway environments.
Tensile Strength 15 N/mm² Resists mechanical stress during installation and operation.

 

III. Compliance with Industry Standards: Meeting Stringent Requirements

ECKABEL SIENOPYR(120) cables conform to critical international and industry-specific standards, ensuring safety, quality, and interoperability:

Standard Description
DIN EN 50264-3-1 Defines fire performance requirements for thin-wall railway rolling stock cables.
DIN EN 45545 Sets fire safety requirements for railway vehicles at hazard levels HL1, HL2, HL3.
IEC 60228 Governs conductors of insulated cables, ensuring durability and reliability.
DIN EN 61034-2 Measures smoke density of cables under fire conditions, vital for safe evacuation.
IEC 60332-3-24 Tests flame spread of cable bunches, ensuring reduced fire propagation.
IEC 60811-404 Tests for material resistance to oils, ensuring performance under challenging conditions.

These certifications guarantee high performance in railway environments while prioritizing safety for passengers and equipment.


IV. Practical Considerations and Potential Challenges: Real-World Applications

Installation Guidelines

Proper installation ensures long-term cable reliability:

Installation Aspect Recommendation
Storage Store in dry conditions, away from UV exposure and mechanical damage.
Handling Avoid sharp bends exceeding bending radius limits.
Routing Secure cables to prevent vibration or abrasion, particularly in bogies.
Termination Use compatible glands and connectors rated for 3.6/6 kV applications.

 

 

Maintenance and Inspection

Periodic inspection and maintenance extend cable service life:

Activity Purpose
Visual Inspection Check for wear, abrasion, and sheath damage.
Electrical Testing Verify insulation integrity and electrical performance.
Replacement Criteria Replace cables showing significant degradation or exceeding service life.

 

 

V. Addressing Specific Challenges

Fire Safety in High-Risk Areas

In environments prone to fire hazards, such as near braking systems or traction motors, SIENOPYR(120) cables mitigate risks by:

  • Providing flame retardancy to prevent rapid fire spread.
  • Generating minimal smoke and toxic gases to aid safe evacuation.

Mechanical Stress and Vibration

Railway bogies and inter-car connections encounter constant vibration and movement. These cables feature:

  • EVA rubber sheaths for enhanced abrasion resistance.
  • Optimized bending properties to endure repetitive motion without cracking.

Limited Space for Installation

In compact railway compartments, these cables offer:

  • Thin-wall construction to save space.
  • Flexible routing options compatible with modern rolling stock designs.

ECKABEL SIENOPYR(120) (N)HXSGAFCHXOE 3,6/6KV: Halogen-Free Cables for Enhanced Fire Safety in Railway Rolling Stock 1


VI. Conclusion: Choosing ECKABEL SIENOPYR(120)

ECKABEL SIENOPYR(120) cables stand out as the ideal solution for fixed wiring and limited flexing applications in railway rolling stock. With a focus on fire safety, halogen-free materials, and robust design, these cables ensure reliability and compliance with international standards.

For enhanced safety, operational efficiency, and compliance, choose ECKABEL SIENOPYR(120) cables for your next railway project. Contact ECKABEL today for technical support or product inquiries.


VII. Appendix

Technical Data Sheet (SIENOPYR(120))

Property Value
Rated Voltage 3.6/6 (7.2) kV
Test Voltage 11 kV
Max Conductor Temperature 120°C
Short Circuit Temperature 250°C
Bending Radius (Fixed) 6 x OD
Bending Radius (Moving) 10 x OD
Fire Standard Compliance DIN EN 45545

This comprehensive table provides easy reference for engineers and procurement specialists.

ECKABEL remains committed to delivering cables that redefine safety, reliability, and performance for the railway industry.

 

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat