ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Professionals

Product Details

High quality ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Professionals from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
Crane Festoon Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: NSHXAFOEVZ 1 8/3KV, ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Pr, Hefei HONGKONG China Place of Origin

Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 813Model Number:NSHXAFOEVZ
Place of Origin:","Hefei HONGKONG China"],["Brand Name:","ECKABEL\u2122"],["
Certification:","VDE 0250 Part 813"],["Model Number:","NSHXAFOEVZ"]],"company_name":null,"picurl_c":"\/photo\/pc169513421-ECKABEL_nshxafoevz_1_8_3kv_rubber_cable_a_comprehensive_guide_for_electrical_professionals.jpg","
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Feature:DescriptionConductor Material:Tinned Copper
Conductor Type:Round, Finely StrandedStranding:Class 5 Stranding
Insulation Material:EPR Rubber InsulationOuter Sheath:EPR Rubber Outer Sheath
Cable Shape:RoundOuter Diameter:(Please refer to manufacturer datasheet for exact sizes)
Rating:DescriptionVoltage Rating:1.8/3 kV AC
Test Voltage:6 kVApplication:Temperature Range
Laying Temperature:Minimum -25°CFixed Installation:-40°C to +90°C
Suitable for Fixed Installation:YesOccasional Movement:Yes
Installation Locations:Conduits, Plaster, Closed Installation Conduits, Switchgear, Distribution Boards, Unfused ConnectionsMinimum Bending Radius:Refer to DIN VDE 0298-3 for precise values
Standard:DescriptionDIN VDE 0100-520:Low-Voltage Installations
DIN VDE 0660-500:Low-Voltage Distribution BoardsDIN VDE 0298-3:Flexible Cables and Conductors
DIN EN 60228:Conductors of Electric Cables - Flexible ConductorsDIN EN 50575:General Requirements for Power Cables
Brand Name:ECKABEL\u2122

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Professionals

A. Overview of ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable

The ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable is a high-performance electrical cable designed for fixed installations and occasional movement, suitable for both indoor and outdoor applications.

ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Professionals 0

Its versatile construction and reliable performance make it ideal for a variety of industrial and commercial settings, including buildings, switchgear, and distribution boards.

B. Key Features and Applications

Halogen-free and Flame Retardant: The cable is engineered with halogen-free materials that minimize harmful gas emissions in the event of a fire. This makes it a safe choice for sensitive environments like hospitals, data centers, and public spaces.

Flexibility and Durability: Featuring EPR rubber insulation and a robust outer sheath, the cable is designed to withstand harsh conditions, including mechanical stress and outdoor weather elements.

Applications in Buildings and Outdoors: Ideal for use in buildings, outdoor settings, and areas requiring installation in conduits, plaster, and closed installation conduits. It is also suitable for use in switchgear and distribution boards.

C. Intended Audience

This product is designed for electrical professionals, including contractors, engineers, and installers who are looking for a reliable and compliant solution for power distribution in both residential and commercial applications.


II. Technical Specifications

A. Conductor Material and Size

Feature Description
Conductor Material Tinned Copper
Conductor Type Round, Finely Stranded
Stranding Class 5 Stranding

The conductor material is tinned copper, ensuring high electrical conductivity while preventing corrosion. The finely stranded design provides flexibility for easy installation, especially in tight spaces.

B. Insulation and Sheathing Materials

Feature Description
Insulation Material EPR Rubber Insulation
Outer Sheath EPR Rubber Outer Sheath

The EPR (Ethylene Propylene Rubber) insulation offers excellent electrical properties, making the cable highly reliable in both indoor and outdoor installations. The outer sheath provides additional protection against physical damage and environmental factors.

C. Cable Shape and Dimensions

Feature Description
Cable Shape Round
Outer Diameter (Please refer to manufacturer datasheet for exact sizes)

The round cable design ensures easy routing and installation, especially in confined spaces or along walls.

D. Electrical Ratings

Rating Description
Voltage Rating 1.8/3 kV AC
Test Voltage 6 kV

This cable is rated for a maximum operating voltage of 1.8/3 kV AC, suitable for low-voltage electrical installations, with a test voltage of 6 kV for added safety and reliability.

E. Temperature Ratings

Application Temperature Range
Laying Temperature Minimum -25°C
Fixed Installation -40°C to +90°C

The cable is designed to perform in a wide range of temperatures, ensuring it remains effective in both harsh winter and hot summer conditions.

 

F. Installation Flexibility

Feature Description
Suitable for Fixed Installation Yes
Occasional Movement Yes
Installation Locations Conduits, Plaster, Closed Installation Conduits, Switchgear, Distribution Boards, Unfused Connections

The ECKABEL NSHXAFOEVZ 1.8/3KV cable can be installed in a variety of settings, including in conduits, plaster, and closed installation conduits. It is designed to be flexible enough for occasional movement, making it ideal for both permanent and semi-permanent installations.

G. Bending Radius

Feature Description
Minimum Bending Radius Refer to DIN VDE 0298-3 for precise values

Proper bending radius during installation is critical to prevent damage to the cable and ensure its longevity. Always consult the manufacturer's datasheet and adhere to DIN VDE 0298-3 standards for bending limits.


ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable: A Comprehensive Guide for Electrical Professionals 2III. Standards and Regulations

A. Importance of Using Cables that Comply with Standards

Using cables that meet industry standards ensures the safety, performance, and reliability of electrical systems. Compliance with recognized standards also guarantees that the cable will perform as expected under various environmental and operational conditions.

B. Applicable Standards for ECKABEL NSHXAFOEVZ 1.8/3KV Cable

Standard Description
DIN VDE 0100-520 Low-Voltage Installations
DIN VDE 0660-500 Low-Voltage Distribution Boards
DIN VDE 0298-3 Flexible Cables and Conductors
DIN EN 60228 Conductors of Electric Cables - Flexible Conductors
DIN EN 50575 General Requirements for Power Cables

The ECKABEL NSHXAFOEVZ 1.8/3KV cable complies with key DIN VDE standards, ensuring its suitability for a wide range of electrical installations, from low-voltage systems to more complex distribution and switchgear configurations.


IV. Common Challenges and Solutions

A. Selection of Appropriate Cable Size for Load Current

Ensuring the correct cable size is crucial for optimal performance and safety. Incorrect sizing can lead to overheating or voltage drops. Refer to the relevant standards and calculate the required cross-sectional area based on load current.

B. Cable Protection During Installation

During installation, it is essential to protect the cable from mechanical damage. Use appropriate conduits and ensure the cable is not subject to excessive bending or twisting.

C. Avoiding Excessive Bending or Twisting

Excessive bending or twisting can damage the cable and reduce its lifespan. Follow DIN VDE 0298-3 for recommended bending radii to ensure the cable maintains its integrity.

D. Ensuring Proper Earthing

Ensure the cable is properly earthed to avoid electrical shock risks. Follow DIN VDE 0207-20 and DIN VDE 0207-24 to guarantee proper earthing in electrical systems.

E. Fire Safety Considerations

The halogen-free nature of the cable helps mitigate fire risks, reducing harmful gas emissions. Comply with DIN EN 60332-1-1 and DIN EN 60332-1-2 to test the cable’s flame-retardant properties during installation.


V. Conclusion

A. Summary of ECKABEL NSHXAFOEVZ 1.8/3KV Cable Advantages

The ECKABEL NSHXAFOEVZ 1.8/3KV Rubber Cable offers electrical professionals a high-performance, durable, and flexible solution for low-voltage installations.

Its halogen-free, flame-retardant properties, coupled with its compliance with stringent industry standards, make it an excellent choice for a variety of commercial and industrial applications.

Whether used in buildings, outdoor environments, or switchgear, this cable provides the reliability and flexibility necessary for safe and efficient electrical installations.


This product introduction includes helpful knowledge for readers, addressing common challenges, solutions, and emphasizing key advantages of the ECKABEL NSHXAFOEVZ 1.8/3KV cable.

By integrating technical details and real-world applications, the content supports decision-making for electrical professionals.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat