ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Application and Safety Guide

Product Details

High quality ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Application and Safety Guide from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
Shipboard & Marine Cables

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: OZOFLEX H07RN-F VG95218T13A, ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Appl, Suited For Underground Mining Underground Ready

Underground Ready:Suited For Underground MiningOperating Temperature:-40°C to 90°C
Waterproof Design:Water-Resistant ConstructionLow Smoke Emission:IEC 61034-1, IEC 61034-2
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 813Model Number:H07RN-F VG95218T13A Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Operating Temperature:-40°C To 90°CFlexibility:Flexible
Application:Marine And Offshore IndustryJacket Material:Rubber
Certifications:ABS, DNV, BV, LR, CCS, NK, RINA, Etc.Easy Termination:Simplifies The Termination Process
Maximum Ampacity:170 AmpsConnector Type:NEMA L5-30P
Impact Resistant:Guards Against Impact DamageCable Type:Flexible
Optimized For Quarrying:Designed For Quarrying ApplicationsComponent:Material
Conductor:Tinned copper wires (Class 5 per IEC 60228)Core insulation:EPR rubber, offering excellent flexibility and thermal resistance
Inner sheath:EPR rubber for enhanced insulation and mechanical protectionOuter sheath:Chlorinated polyethylene (CM/CPE), providing durability and oil resistance
Parameter:ValueRated voltage:450/750V (U0/U)
Test voltage:2.5kVMaximum conductor temp.:60°C
Short circuit temp.:200°CSpecification:Value
Ambient temperature:Fixed installations: -25°CMinimum laying temp.:-40°C
Flame retardancy:EN/IEC 60332-1-2 compliantOil resistance:IEC/EN 60811-404 compliant
Ozone resistance:EN 50363-1 and EN 50363-2-1Ambient Temp (°C):Correction Factor
30:1.035:0.9
40:0.845:0.7
50:0.6Standard:Details
VG 95218-63:Construction and performance requirementsEN 60079 Series:Explosive atmosphere safety
IEC 60228:Conductor requirementsDIN VDE 0298 Part 300:Installation guidelines
Operating Temperature:-40\u00b0C to 90\u00b0C

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Application and Safety Guide

When it comes to reliable, durable, and versatile rubber-insulated cables, the ECKABEL OZOFLEX H07RN-F VG95218T13A stands out as a top choice for industrial, agricultural, and construction applications.

Designed to meet the stringent VG 95218 Part 13A standards, this cable delivers exceptional performance in dry, humid, or moist environments and is resistant to oil, ozone, and flames.

This article explores:

  • The technical strengths of the ECKABEL OZOFLEX H07RN-F cable series.
  • Applications where it excels, including transportable motors, workshop appliances, and hazardous areas.
  • Detailed installation and maintenance guidelines to maximise performance and safety.

2. Technical Specifications and Construction

2.1 Cable Construction

The ECKABEL OZOFLEX H07RN-F is built for robustness and flexibility. Its construction includes:

Component Material
Conductor Tinned copper wires (Class 5 per IEC 60228)
Core insulation EPR rubber, offering excellent flexibility and thermal resistance
Inner sheath EPR rubber for enhanced insulation and mechanical protection
Outer sheath Chlorinated polyethylene (CM/CPE), providing durability and oil resistance

Key Benefits:

  • Tinned copper conductors: Resist corrosion, ensuring reliable electrical performance in harsh environments.
  • EPR rubber insulation: Withstands high temperatures and mechanical stress, making it ideal for heavy-duty use.
  • CPE outer sheath: Protects against oil, ozone, and mechanical wear.

2.2 Electrical Characteristics

The cable's electrical performance is optimised for industrial and agricultural applications:

Parameter Value
Rated voltage 450/750V (U0/U)
Test voltage 2.5kV
Maximum conductor temp. 60°C
Short circuit temp. 200°C

2.3 Environmental Specifications

Designed for extreme conditions, this cable performs reliably across a wide temperature range:

Specification Value
Ambient temperature Fixed installations: -25°C
Minimum laying temp. -40°C
Flame retardancy EN/IEC 60332-1-2 compliant
Oil resistance IEC/EN 60811-404 compliant
Ozone resistance EN 50363-1 and EN 50363-2-1

3. Hazardous Area Applications

3.1 Explosive Atmosphere Considerations

The ECKABEL OZOFLEX H07RN-F is suited for areas with explosive or flammable atmospheres, compliant with the EN 60079 series. Important considerations include:

  • Zone classification: Identify the type of hazardous area to ensure compatibility.
  • Installation guidelines: Follow specific recommendations for explosive atmospheres to ensure safety.

3.2 Safety Requirements

  • Risk assessments: Regular evaluations are critical to identify hazards.
  • Certification: Ensure compliance with regulatory standards before use.
  • Inspection: Routine checks are essential to maintain safety.

 

4. Application Areas and Installation Guidelines

4.1 Application Areas

The ECKABEL OZOFLEX H07RN-F is versatile and performs well in:

  • Industrial settings: Powering transportable motors and large workshop appliances.
  • Construction sites: Connecting tools like drills, saws, and heating plates.
  • Agriculture: Supporting machinery in fields and processing facilities.
  • Explosive atmospheres: Providing safe electrical connections in hazardous zones.

4.2 Installation Methods

To maximise the cable's performance and lifespan, adhere to the following:

4.2.1 Fixed Installations

Bending radius:

D ≤ 8mm: 3 × D

8 < D ≤ 12mm: 3 × D

12 < D ≤ 20mm: 4 × D

D > 20mm: 4 × D

Securing methods: Use proper clamps to minimise movement.

Protection: Shield cables from excessive heat and moisture.

4.2.2 Flexible Applications

Bending radius:

D ≤ 8mm: 5 × D

8 < D ≤ 12mm: 5 × D

12 < D ≤ 20mm: 6 × D

D > 20mm: 6 × D

Movement considerations: Use strain relief devices to prevent tension damage.


ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Application and Safety Guide 1

 

5. Environmental Considerations

5.1 Chemical Resistance

The ECKABEL OZOFLEX H07RN-F is engineered to resist:

  • Oil: Meets IEC/EN 60811-404 standards.
  • Ozone: Compliant with EN 50363-1 and EN 50363-2-1.

5.2 Temperature Management

Proper management of ambient temperatures is critical:

  • Correction factors: Use derating tables to account for elevated temperatures.
  • Installation impacts: Consider heat dissipation in enclosed spaces.
Ambient Temp (°C) Correction Factor
30 1.0
35 0.9
40 0.8
45 0.7
50 0.6

ECKABEL OZOFLEX H07RN-F VG95218T13A Rubber-Insulated Cables - Comprehensive Application and Safety Guide 2

 

6. Installation Challenges and Solutions

6.1 Common Installation Issues

  • Space constraints: Opt for flexible routing techniques.
  • Environmental factors: Protect against oil, UV, and mechanical impacts.

6.2 Troubleshooting Guide

  • Common faults: Insulation wear, mechanical damage, and improper termination.
  • Solutions: Regular inspections and timely repairs ensure longevity.

7. Quality Assurance and Testing

7.1 Standards Compliance

The cable meets all critical standards:

  • VG 95218-63 and VG 95218-2.
  • DIN VDE 0298 Part 300 for installation.

7.2 Testing Procedures

  • Pre-installation: Verify dimensions and integrity.
  • Post-installation: Perform electrical and mechanical testing.

8. Maintenance and Lifecycle Management

8.1 Routine Maintenance

Regular checks ensure safety and functionality:

  • Inspect terminations and insulation.
  • Monitor performance and document findings.

8.2 Lifecycle Considerations

  • Replace cables showing significant wear or reduced performance.
  • Upgrade to newer standards as needed.

9. References and Supporting Documentation

Standard Details
VG 95218-63 Construction and performance requirements
EN 60079 Series Explosive atmosphere safety
IEC 60228 Conductor requirements
DIN VDE 0298 Part 300 Installation guidelines

10. Appendices

Appendix A: Temperature Correction Factors

Ambient Temp (°C) Correction Factor
30 1.0
35 0.9
40 0.8

Appendix B: Installation Checklists

  • Verify cable dimensions.
  • Ensure correct bending radii.
  • Document test results.

The ECKABEL OZOFLEX H07RN-F VG95218T13A offers reliability and versatility, making it a top choice for demanding environments. With proper installation and maintenance, it ensures safety, efficiency, and durability for years to come.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat