ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

Product Details

High quality ECKABEL SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
Shipboard & Marine Cables

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SIENOPYR FR MHXCH FE 120, ECKABEL SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehens, Yes Uv Resistance

Uv Resistance:YesLength:Customizable
Standards:NEC, NFPA 70Jacket Material:Neoprene
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 813Model Number:SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Water Resistant:YesSturdy Connector Design:Solid Connector Construction
Voltage:0.6/1kVNumber Of Conductors:3
Resistance:Oil, Chemicals, AbrasionFlexible:Yes
Current Rating:1000AOptimized For Quarrying:Designed For Quarrying Applications
Conductor Integrity:Reliable Conductor IntegrityArmour Type:Galvanized Steel Wire Braid
Component:MaterialConductor:Plain copper, round stranded
Insulation:Silicone rubberScreen:Copper braiding
Outer Sheath:Halogen-free flame-retardant (HFFR)Core Identification:Colour-coded (HD 308 S2)
Feature:SpecificationFire Resistance Rating:FE 120 (Circuit integrity under fire conditions)
Flame Retardance:IEC 60332-1-2 / IEC 60332-3-22Low Smoke Emission:IEC 61034
Halogen-Free:IEC 60754-1/2Parameter:Value
Rated Voltage:0.6/1kV (Um: 1.2kV)Test Voltage:3.5kV
Maximum Conductor Temp.:90°CShort Circuit Temp.:250°C
Minimum Laying Temp.:-15°CStandard:Requirement
IEC 60332-1-2:Resistance to flame propagationIEC 60332-3-22:Enhanced flame retardance for bundled cables
FE 120:Circuit integrity during 120 minutes of fireRequirement:Specification
Bending Radius:Minimum 6 × ODFire-Rated Penetrations:For bulkhead transitions
Support Systems:Fire-resistant cable traysFeature:Benefit
Oil Resistance:Withstands exposure to lubricants (IEC 60811-404).Ozone Resistance:Prevents degradation in ozone-rich environments.
Salt Spray Protection:Ensures corrosion resistance in coastal areas.UV Protection:Guards against sun exposure damage.
Condition:Maximum PerformanceNormal Operation Temp.:Up to 90°C
Short Circuit Temp.:Up to 250°CRigorous Testing:Ensures product reliability.
Traceability Systems:Facilitates easy certification.

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide

In the demanding world of marine and offshore installations, fire-resistant cables are critical to ensuring the integrity and safety of emergency systems. The ECKABEL SIENOPYR FR MHXCH FE 120 cable is engineered to provide exceptional fire resistance, enabling critical circuits to function reliably under extreme conditions.

Designed specifically for fixed installations in all locations aboard ships and offshore units, these cables are robust, durable, and meet stringent international fire safety standards. However, it's important to note that these cables are not suitable for continuous water immersion, making proper installation planning vital.


 

 

2. Technical Specifications

The ECKABEL SIENOPYR FR MHXCH FE 120 cable boasts advanced materials and construction techniques. Below is a detailed overview of its specifications:

 

 

2.1 Cable Construction

Component Material Standard Compliance
Conductor Plain copper, round stranded IEC 60228 (Class 2 or 5)
Insulation Silicone rubber High-temperature resilience
Screen Copper braiding Provides excellent EMC shielding
Outer Sheath Halogen-free flame-retardant (HFFR) IEC 60092-360
Core Identification Colour-coded (HD 308 S2) Simplifies installation

 

 

2.2 Fire Performance

Feature Specification
Fire Resistance Rating FE 120 (Circuit integrity under fire conditions)
Flame Retardance IEC 60332-1-2 / IEC 60332-3-22
Low Smoke Emission IEC 61034
Halogen-Free IEC 60754-1/2

2.3 Electrical Characteristics

Parameter Value
Rated Voltage 0.6/1kV (Um: 1.2kV)
Test Voltage 3.5kV
Maximum Conductor Temp. 90°C
Short Circuit Temp. 250°C
Minimum Laying Temp. -15°C

3. Emergency System Applications

SIENOPYR FR MHXCH FE 120 cables are indispensable for critical emergency circuits in marine environments. Below are some typical applications:

3.1 Critical Systems Integration

  • Fire Pump Circuits: Maintain water flow for fire suppression during emergencies.
  • Emergency Lighting Systems: Illuminate escape routes, ensuring safe evacuation.
  • Evacuation Systems: Power lifeboat davits and emergency alarms.
  • Safety Communication Networks: Support reliable communication during crises.

3.2 System Design Requirements

  • Circuit Segregation: Reduces the risk of cascading failures.
  • Redundancy Considerations: Ensures backup systems remain functional.
  • Emergency Power Sources: Designed for connection to dedicated emergency generators.

4. Fire Safety Standards

The ECKABEL SIENOPYR FR MHXCH FE 120 cable complies with rigorous fire safety standards, offering unmatched protection in critical environments.

4.1 Fire Performance Standards

Standard Requirement
IEC 60332-1-2 Resistance to flame propagation
IEC 60332-3-22 Enhanced flame retardance for bundled cables
FE 120 Circuit integrity during 120 minutes of fire

4.2 Smoke and Toxicity

  • Low Smoke Emission: Reduces visibility loss during fire (IEC 61034).
  • Halogen-Free Materials: Prevents toxic gas release (IEC 60754).

5. Marine Installation Requirements

Marine environments demand careful installation practices to ensure long-term reliability.

5.1 Location-Specific Installation

  • Engine Rooms: Require flame-retardant and heat-resistant cables.
  • Escape Routes: Must use FE 120-rated cables for critical evacuation circuits.
  • Weather Decks: Use UV and ozone-resistant materials to withstand harsh conditions.

5.2 Installation Methods

Requirement Specification
Bending Radius Minimum 6 × OD
Fire-Rated Penetrations For bulkhead transitions
Support Systems Fire-resistant cable trays

6. Environmental Protection

These cables are built to endure harsh environmental conditions typical of marine applications.

6.1 Environmental Resistance

Feature Benefit
Oil Resistance Withstands exposure to lubricants (IEC 60811-404).
Ozone Resistance Prevents degradation in ozone-rich environments.
Salt Spray Protection Ensures corrosion resistance in coastal areas.
UV Protection Guards against sun exposure damage.

6.2 Temperature Management

Condition Maximum Performance
Normal Operation Temp. Up to 90°C
Short Circuit Temp. Up to 250°C

7. Installation Challenges and Solutions

7.1 Common Challenges

  • Maintaining fire barrier integrity during cable routing.
  • Ensuring EMC compliance for sensitive circuits.
  • Preventing moisture ingress in humid conditions.

7.2 Best Practice Solutions

  • Fire Zone Separation: Proper segregation reduces fire spread risk.
  • Support Systems: Use fire-rated trays and clamps for secure installations.
  • Termination Techniques: Employ EMC glands for seamless connections.

8. Testing and Verification

8.1 Pre-Installation Testing

  • Fire Resistance Testing: Ensures compliance with FE 120 standards.
  • Screen Continuity Checks: Validates EMC shielding effectiveness.

8.2 System Integration Testing

  • Emergency Circuit Validation: Confirms operational integrity under fire conditions.
  • Performance Monitoring: Detects potential faults early.

 

ECKABEL SIENOPYR FR MHXCH FE 120 Fire-Resistant Marine Power Cables - Comprehensive Emergency System Application Guide 1

 

9. Maintenance and Inspection

9.1 Regular Maintenance

  • Visual inspections for mechanical damage.
  • Testing for insulation integrity.
  • Monitoring performance metrics.

9.2 Emergency Response Planning

  • Develop recovery protocols for damaged circuits.
  • Train personnel on emergency repair strategies.

10. Quality Assurance

10.1 Manufacturing Standards

Feature Benefit
Rigorous Testing Ensures product reliability.
Traceability Systems Facilitates easy certification.

10.2 Installation Quality

Adherence to classification society rules ensures safe and reliable cable installations.


 

 

11. Conclusion

The ECKABEL SIENOPYR FR MHXCH FE 120 cable is a highly reliable solution for fire-resistant power supply in marine and offshore environments. Its compliance with stringent standards ensures the safety and functionality of critical emergency systems during extreme conditions.

For inquiries or to learn more about how these cables can enhance your marine installations, contact ECKABEL Cable today!

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat