ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

Type SHD-GC 2kV Mining Reeling Trailing 3 AWG 3C Power Cable

Product Details

High quality Type SHD-GC 2kV Mining Reeling Trailing 3 AWG 3C Power Cable from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
CSA & MSHA Mining Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SHD-GC 3 AWG 3C, Mining Reeling Trailing 3 AWG 3C Power Cable, Type SHD-GC 2kV Mining Reeling Trailing 3 AWG 3C Power Cable

Safe Excavation:Minimizes Fire RisksSunlight Resistance:Yes
Temperature Rating:-40°C to 90°CInnovative Design:Cutting-edge Engineering
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:DiN VDE 0295 Class 5 & DiN VDE 0207Model Number:Type SHD-GC 2kV Mining Reeling Trailing 3 AWG 3C Power Cable Payment & Shipping Terms
Minimum Order Quantity:1000 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Temperature Rating:-40°C To 90°CType:SHD GC Cable
Insulation Material:EPDMWater Resistance:Yes
Application:OutdoorCorrosion Resistance:Withstands Harsh Conditions
Bulk Material Handling:Efficient Material TransportSpecification:Details
Cable Type:SHD-GC Mining Reeling Trailing Power CableVoltage Rating:2000 Volts (2kV)
Number of Conductors:3 Conductors + Ground + Ground CheckConductor Size:3 AWG, 259 strands
Insulation Material:Ethylene Propylene Rubber (EPR)Insulation Thickness:1.8 mm (0.070 inches)
Outside Diameter:38.3 mm (1.51 inches)Net Weight:0.76 kg/m (1.68 lbs per ft)
Current Capacity:140 AMPSAttribute:Details
AWG Size:7 AWGMaterial:Bare Copper
Purpose:Provides safety by carrying fault currentsAWG Size:10 AWG
Insulation Material:PolypropylenePurpose:Monitors the cable's grounding system for integrity
Insulation Temperature Rating:90°C Continuous OperationVoltage Ratings:Available in 2kV, 5kV, 8kV, 15kV, and 25kV configurations
Material Benefits:Superior dielectric strength, long service lifeMaterial:Feature
Ethylene Propylene Rubber (EPR):Exceptional dielectric strength, moisture, and heat resistanceChlorinated Polyethylene (CPE):Outer jacket material, resistant to UV, chemicals, and abrasion
Application:ExamplesMining Equipment:Continuous miners, shuttle cars, loaders
Material Handling Machines:Stackers, reclaimers, and conveyorsPort Operations:Electrified rubber-tired gantry cranes, ship unloaders
Heavy Mobile Equipment:Excavators, bulldozers, and haul trucksStandard:Compliance
MSHA Regulations:Approved for mining safetyIEEE Guidelines:Meets power cable specifications
IEC Standards:Ensures compatibility with global industrial systemsNFPA Requirements:Fire-retardant and flame-tested
NO. OF COND.:COND. SIZE (AWG/COND. STRAND:NOMINAL INSULATION THICKNESS
GRD. COND. SIZE (AWG):GRD-CHECK COND. SIZE (AWG)NOMINAL JACKET THICKNESS:NOMINAL CABLE 0.D.
mm:mm3:6
133:1.810:10
3.9:32.83:4
259:1.88:10
3.9:35.63:3
7:104.3:38.3
3:26:8
4.3:40.43:1
259:25:8
4.8:44.73:1/0
4:84.8:47.2
3:2/0329:2
3:85.2:50.8
3:3/0413:2
2:85.2:54.1
3:4/0532:2
1:85.6:58.7
3:250608:2.4
1/0:65.6:63.8
3:300741:2.4
6:68.13:350
851:2.42/0:6
6.4:71.43:500
1221:2.44/0:6
6.7:81Guideline:Recommendation
Cable Handling:Avoid sharp bends; maintain minimum bend radiusEnvironmental Suitability:Designed for underground and surface applications
Protection:Use guards against sharp objectsInspection Type:Frequency
Visual Checks:MonthlyElectrical Tests:Semi-annually
Mechanical Integrity Tests:AnnuallyRisk:Mitigation
Electrical Faults:Robust ground conductors and electrical isolationMechanical Damage:Durable CPE jacket with abrasion resistance
Fire Hazards:Flame-retardant propertiesTemperature Rating:-40\u00b0C to 90\u00b0C

Payment & Shipping Terms

Minimum Order Quantity:1000 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

Type SHD-GC 2kV Mining Reeling Trailing Power Cable: Engineered for Demanding Industrial Applications

 

The ECKABEL Type SHD-GC 2kV Mining Reeling Trailing Power Cable is a cutting-edge solution tailored for heavy-duty mining and industrial operations.

Designed with advanced engineering and robust materials, this cable ensures reliable power transmission, even under extreme environmental conditions.

This comprehensive guide explores the cable's technical specifications, engineering features, primary applications, compliance standards, and installation guidelines to help readers understand its performance and reliability.


Product Specification Overview

The Type SHD-GC Power Cable is built to meet the demands of mining equipment, stackers and reclaimers, and other heavy machinery. Its robust construction and advanced materials deliver superior performance. Below is an overview of its key specifications.

Specification Details
Cable Type SHD-GC Mining Reeling Trailing Power Cable
Voltage Rating 2000 Volts (2kV)
Number of Conductors 3 Conductors + Ground + Ground Check
Conductor Size 3 AWG, 259 strands
Insulation Material Ethylene Propylene Rubber (EPR)
Insulation Thickness 1.8 mm (0.070 inches)
Outside Diameter 38.3 mm (1.51 inches)
Net Weight 0.76 kg/m (1.68 lbs per ft)
Current Capacity 140 AMPS

 

 

Conductor and Insulation Specifications

1. Ground Conductor

Attribute Details
AWG Size 7 AWG
Material Bare Copper
Purpose Provides safety by carrying fault currents

2. Ground Check Conductor

Attribute Details
AWG Size 10 AWG
Insulation Material Polypropylene
Purpose Monitors the cable's grounding system for integrity

3. Insulation and Temperature Ratings

The Type SHD-GC Cable incorporates EPR insulation, offering exceptional resistance to heat, moisture, and chemicals.

Attribute Details
Insulation Temperature Rating 90°C Continuous Operation
Voltage Ratings Available in 2kV, 5kV, 8kV, 15kV, and 25kV configurations
Material Benefits Superior dielectric strength, long service life

Key Engineering Features

1. Advanced Material Technology

Material Feature
Ethylene Propylene Rubber (EPR) Exceptional dielectric strength, moisture, and heat resistance
Chlorinated Polyethylene (CPE) Outer jacket material, resistant to UV, chemicals, and abrasion

These materials enable the cable to withstand extreme conditions, ensuring long-term reliability and safety.

2. 3+3 Construction Design

The three-conductor design includes three power conductors and three ancillary components (ground and ground check). This configuration ensures:

  • Mechanical stability during high-flex applications.
  • Improved durability under constant reeling and trailing.
  • Optimized performance for dynamic industrial environments.

3. Integrated Fiber Optics (Optional)

For advanced monitoring and control, the cable can support fiber optic cores, enabling simultaneous power and data transmission.


Application Domains

1. Primary Industrial Applications

The Type SHD-GC Power Cable is ideal for mining and industrial equipment that require high power delivery under tough conditions.

Application Examples
Mining Equipment Continuous miners, shuttle cars, loaders
Material Handling Machines Stackers, reclaimers, and conveyors
Port Operations Electrified rubber-tired gantry cranes, ship unloaders
Heavy Mobile Equipment Excavators, bulldozers, and haul trucks

 

 

2. Extreme Environmental Conditions

The cable is specially designed for underground mining, surface operations, and areas with chemical exposure, abrasive surfaces, or extreme temperatures.


Performance Advantages

1. Exceptional Mechanical Resilience

  • Abrasion Resistance: Protects against cuts and scrapes.
  • Puncture Resistance: Withstands mechanical shocks.
  • Tear Resistance: Ideal for dynamic reeling applications.

2. High Reliability in Tough Environments

The SHD-GC Cable maintains consistent performance in:

  • Wet or dry conditions.
  • High-heat zones.
  • Cold climates.

Compliance and Certification

The Type SHD-GC Cable adheres to stringent international safety and performance standards:

Standard Compliance
MSHA Regulations Approved for mining safety
IEEE Guidelines Meets power cable specifications
IEC Standards Ensures compatibility with global industrial systems
NFPA Requirements Fire-retardant and flame-tested
TYPE SHD-GC - 2000 VOLTS Round
NO. OF COND. COND. SIZE (AWG/ COND. STRAND NOMINAL INSULATION THICKNESS GRD. COND. SIZE (AWG) GRD-CHECK COND. SIZE (AWG) NOMINAL JACKET THICKNESS NOMINAL CABLE 0.D. NET WEIGHT
kg/ km
mm mm mm
3 6 133 1.8 10 10 3.9 32.8 1682
3 4 259 1.8 8 10 3.9 35.6 2173
3 3 259 1.8 7 10 4.3 38.3 2500
3 2 259 1.8 6 8 4.3 40.4 2961
3 1 259 2 5 8 4.8 44.7 3549
3 1/0 259 2 4 8 4.8 47.2 4115
3 2/0 329 2 3 8 5.2 50.8 4844
3 3/0 413 2 2 8 5.2 54.1 5789
3 4/0 532 2 1 8 5.6 58.7 7024
3 250 608 2.4 1/0 6 5.6 63.8 8125
3 300 741 2.4 1/0 6 6 68.1 9517
3 350 851 2.4 2/0 6 6.4 71.4 10834
3 500 1221 2.4 4/0 6 6.7 81 14614

Installation and Maintenance Considerations

1. Best Practices for Installation

Proper handling during installation ensures optimal performance and longevity.

Guideline Recommendation
Cable Handling Avoid sharp bends; maintain minimum bend radius
Environmental Suitability Designed for underground and surface applications
Protection Use guards against sharp objects

 

 

2. Maintenance and Inspection

Regular inspections ensure the cable's integrity and reliability.

Inspection Type Frequency
Visual Checks Monthly
Electrical Tests Semi-annually
Mechanical Integrity Tests Annually

Technical Risk Mitigation

The Type SHD-GC Cable addresses common risks in industrial and mining applications:

Risk Mitigation
Electrical Faults Robust ground conductors and electrical isolation
Mechanical Damage Durable CPE jacket with abrasion resistance
Fire Hazards Flame-retardant properties

Conclusion

The ECKABEL Type SHD-GC 2kV Mining Reeling Trailing Power Cable is a premium solution for critical power transmission in the most challenging industrial environments. Its advanced engineering and robust materials ensure unmatched reliability, mechanical strength, and long-term safety.

Why Choose ECKABEL SHD-GC Cable?

  • Durable Materials: EPR insulation and CPE jacket for extreme conditions.
  • High Performance: Consistent power delivery under dynamic loads.
  • Global Compliance: Certified to meet rigorous safety standards.

Technical Support and Consultation

For detailed technical assistance or custom configurations, contact the ECKABEL Technical Support Team today.

  • Custom Solutions: Voltage ratings, cable lengths, and additional features.
  • Expert Guidance: Installation and maintenance best practices.

Empower your operations with ECKABEL SHD-GC Power Cables — designed for excellence.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote