ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1KV Coal Cutter Cables for Chain Operation with Concentric Earth Conductor

Product Details

High quality ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1KV Coal Cutter Cables for Chain Operation with Concentric Earth Conductor from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
DIN VDE 0118-10 Mining Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: PROTOMONT NSSHCGEOEU 0, ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1KV Coal Cutter Cables for Chain Operation , -25°C to +60°C Temperature Rating

Temperature Rating:-25°C to +60°CInsulation Material:EPR (Ethylene Propylene Rubber)
Flexible:YesStandards:VDE 0118-10
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™ Mining
Certification:VDE 0250 Part 813Model Number:NSSHCGEOEU Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Temperature Rating:-25°C To +60°CConductor Material:Flexible Stranded Copper
Jacket Material:PUR CableCertifications:IEC, ASTM, CSA, UL
Abrasion Resistant:YesFiller:Optional
Sheath Material:PCP (Polychloroprene)Type:PER Rubber Mining Cable
Number Of Cores:3+3+1Feature:Specification
Product Configuration:3x95/50KON + 3x(1.5STKON/1.5UELKON)Rated Voltage [U0/U (Um)]:0.6/1 (1.2) kV
Nominal Voltage:1000VCable Composition:Three main power cores, concentric earth conductor, and control/monitoring cores
Conductor Material:Very finely stranded copper, tinned (Class FS)Core Coloration:Main Cores: Black, Grey, Brown – Control Cores: Blue
Earth Conductor:Steel-copper strands, helically applied between inner and outer sheathsCore Insulation:PROTOLON-Special Compound 3GI3 (EPR Rubber)
Max Continuous Conductor Temp:90°CMax Short-Circuit Temp:250°C
Fixed Installation Temp Range:-40°C to +80°CFlexible Installation Temp Range:-20°C to +60°C
Layer:Material DetailsConductor Layer:Very finely stranded, tinned copper for maximum conductivity and flexibility
Insulation System:Semi-conductive NBR easy-strip with EPR rubber for superior dielectric strength and mechanical protectionSheath Construction:Inner: Special EPR Compound GM1b – Outer: Rubber - Polychloroprene (PCP) PROTOFIRM Compound GM5
Earth Conductor:Steel-copper strands helically applied for durability and conductivityResistance Type:Compliance Standard
Flame Retardant:EN/IEC 60332-1-2Oil Resistance:Excellent
Ozone Resistance:SuperiorUV Resistance:Robust
Parameter:SpecificationTorsional Stress:±25°/m
Permanent Tensile Strength:15 N/mm²Bending Radius:Standard: 2.3 × Diameter – S-type changes: 20 × Diameter
Region:CertificationBosnia-Herzegovina:BAS Certification
Eurasian Economic Union:EAC CertificationUnited States:MSHA P-07-KA140034
China:MA CertificationConsideration:Recommendation
Cable Handling:Respect minimum bending radius; avoid mechanical damageEnvironmental Factors:Verify compatibility with the site; conduct pre-installation tests
Cable Chain Management:Ensure proper routing and tension adjustmentsTest Voltage:3 kV
Control Cores Test Voltage:2 kVMaximum Operating Voltage:1 kV
Temperature Rating:-25\u00b0C to +60\u00b0C

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1KV Coal Cutter Cables for Chain Operation with Concentric Earth Conductor

The ECKABEL PROTOMONT (V) NSSHCGEOEU Coal Cutter Cables represent the cutting edge of low-voltage cable technology, engineered specifically for underground mining environments.

Designed to deliver maximum durability and operational efficiency, these cables are the ideal solution for coal cutting machines and other mobile equipment that require dynamic cable chain systems.

This article provides an in-depth look at the technical features, application advantages, and practical installation guidance to ensure optimal performance.


Product Positioning

The ECKABEL PROTOMONT (V) NSSHCGEOEU is a specialized low-voltage power supply connection cable designed for:

Mobile equipment and machinery in underground mining operations.

Coal cutting machines, where dynamic movement and mechanical stress are prevalent.

Use in cable protection chains, withstanding constant flexing and tensile forces.

By leveraging advanced materials and innovative design, this cable ensures safe, reliable power transmission in the harshest mining environments.


Technical Specifications

Fundamental Characteristics

Feature Specification
Product Configuration 3x95/50KON + 3x(1.5STKON/1.5UELKON)
Rated Voltage [U0/U (Um)] 0.6/1 (1.2) kV
Nominal Voltage 1000V
Cable Composition Three main power cores, concentric earth conductor, and control/monitoring cores

 

 

Conductor Specifications

Feature Specification
Conductor Material Very finely stranded copper, tinned (Class FS)
Core Coloration Main Cores: Black, Grey, Brown – Control Cores: Blue
Earth Conductor Steel-copper strands, helically applied between inner and outer sheaths
Core Insulation PROTOLON-Special Compound 3GI3 (EPR Rubber)

 

 

Thermal Performance Parameters

Feature Specification
Max Continuous Conductor Temp 90°C
Max Short-Circuit Temp 250°C
Fixed Installation Temp Range -40°C to +80°C
Flexible Installation Temp Range -20°C to +60°C

ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1KV Coal Cutter Cables for Chain Operation with Concentric Earth Conductor 1

 

Advanced Material Engineering

Comprehensive Layer Composition

Layer Material Details
Conductor Layer Very finely stranded, tinned copper for maximum conductivity and flexibility
Insulation System Semi-conductive NBR easy-strip with EPR rubber for superior dielectric strength and mechanical protection
Sheath Construction Inner: Special EPR Compound GM1b – Outer: Rubber - Polychloroprene (PCP) PROTOFIRM Compound GM5
Earth Conductor Steel-copper strands helically applied for durability and conductivity

 

 

Environmental Resistance

Resistance Type Compliance Standard
Flame Retardant EN/IEC 60332-1-2
Oil Resistance Excellent
Ozone Resistance Superior
UV Resistance Robust

Mechanical Performance Characteristics

Stress Resistance

Parameter Specification
Torsional Stress ±25°/m
Permanent Tensile Strength 15 N/mm²
Bending Radius Standard: 2.3 × Diameter – S-type changes: 20 × Diameter

Compliance and Certification

The ECKABEL PROTOMONT (V) NSSHCGEOEU complies with international standards, ensuring safety and reliability:

Electrical Standards

  • DIN VDE 0250-812

  • DIN EN 60228 / IEC 60228 / VDE 0295

  • DIN VDE 0298-4

  • DIN EN 60332-1-2 / IEC 60332-1-2

  • DIN EN 60811-404 / IEC 60811-404

 

 

Regulatory Approvals

Region Certification
Bosnia-Herzegovina BAS Certification
Eurasian Economic Union EAC Certification
United States MSHA P-07-KA140034
China MA Certification

Application Domains

Recommended Use

Underground mining equipment, particularly coal cutting machines.

Cable chain systems, where constant motion demands high durability.

Low-voltage power transmission in extreme conditions.


Installation Considerations

Best Practices

Consideration Recommendation
Cable Handling Respect minimum bending radius; avoid mechanical damage
Environmental Factors Verify compatibility with the site; conduct pre-installation tests
Cable Chain Management Ensure proper routing and tension adjustments

 

 

Regular Maintenance

To extend the lifespan and ensure the reliability of ECKABEL cables:

Conduct regular visual inspections.

Perform electrical integrity tests at scheduled intervals.

Train personnel in specialized handling techniques.


Technical Risk Mitigation

Safety Features

Multi-layer insulation for enhanced electrical safety.

Concentric earth conductor for effective grounding.

High resistance to mechanical stress, oils, and environmental hazards.

Expert Recommendations

Conduct site-specific cable routing analysis.

Develop a preventive maintenance schedule.

Use specialized cable management systems for optimal performance.


Electrical Performance Highlights

Parameter Specification
Test Voltage 3 kV
Control Cores Test Voltage 2 kV
Maximum Operating Voltage 1 kV

Conclusion

The ECKABEL PROTOMONT (V) NSSHCGEOEU 0.6/1kV Coal Cutter Cables are designed to address the specific challenges of underground mining operations. From superior materials to rigorous safety standards, this cable ensures reliable power transmission, even in the harshest conditions.

With advanced design features such as concentric earth conductors and EPR insulation, this cable offers unparalleled performance and durability.

For detailed technical support or application-specific guidance, contact the ECKABEL Technical Solutions Team.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat