ECKABEL VFD-BGC Power Cable: Advanced Portable Power Solution for Critical Industrial Applications

Product Details

High quality ECKABEL VFD-BGC Power Cable: Advanced Portable Power Solution for Critical Industrial Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
DIN VDE 0118-10 Mining Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: VFD-BGC, Power Cable, ECKABEL VFD-BGC Power Cable: Advanced Portable Power Solution for Critical Indus

Abrasion Resistant:YesReliable Transmission:Ensures Consistent Power Transmission
Stranding:Class B strandedLong Lifespan:Ensures Enduring Durability
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™ Mining
Certification:ICEA S-75-381/NEMA WC 58 ASTM B-8 CAN/CSA-C22.2 No.96Model Number:VFD-BGC Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Stranding:Class B StrandedCorrosion Resistance:Withstands Harsh Conditions
Bulk Material Handling:Efficient Material TransportConnector Type:LC/SC/FC/ST
Abrasion Resistance:HighWater Resistance:Yes
Type:VFD-BGC CableInnovative Design:Cutting-edge Engineering
Reliable Performance:Consistent Operational ExcellenceFeature:Details
Cable Type:ECKABEL Brand Type VFD-BGC Power CableVoltage Rating:2000 Volts
Temperature Range:Up to 90°CConductor Design:Three-Conductor Design
Innovation:DescriptionGround-Check Conductor:Specialized conductor minimizes failure risks and monitors integrity
EMI Shielding:Advanced design reduces electromagnetic interference (EMI)Mechanical Protection:Enhanced system provides superior resistance to impact and abrasion
Property:DetailsMaterial:Coated Annealed Copper
Conductor Size Range:2 AWG through 500 kcmilStranding:Rope-lay stranded, ASTM B172-compliant
Ground-Check Design:Extensible, high-flex conductorInsulation Feature:Details
Material:Ethylene Propylene Rubber (EPR)Core Insulation:High-strength polypropylene
Dielectric Strength:Rated for 2000 voltsJacket Property:Details
Material:Chlorinated Polyethylene (CPE)Construction:Two-layer, lead-cured, extra-heavy-duty
Resistance Properties:Heat, moisture, oil, chemicals, and UVShielding Feature:Details
Shield Type:Flexible copper braid and aluminum tapeTransfer Impedance:Low transfer impedance for EMI suppression
Symmetrical Grounding:Prevents current imbalancesResistance Type:Advantage
Impact:Withstands accidental drops and collisionsAbrasion:Protects against wear from rough handling
Flame:Meets stringent fire safety requirementsUV and Sunlight:Ensures long-term outdoor performance
Electrical Feature:BenefitCommon Mode Current Control:Reduces harmonics for smoother motor operation
Noise Suppression:Advanced EMI shielding minimizes signal disturbancesGround Monitoring:Provides fail-safe detection of ground faults
Certification:StandardMSHA Approval:Certified for mining safety
Flame Test Compliance:Meets stringent flame resistance standardsEnvironmental Approvals:Certified by the Pennsylvania Department of Environmental Protection
Application:DescriptionMining Equipment:Ideal for trailing cables in rugged underground settings
VFD Systems:Optimized for PWM-driven variable frequency drivesMotor Interfaces:Reliable connections in dynamic motor operations
Scenario:Example Use CaseInverter-to-Motor:High-efficiency connections in EMI-heavy environments
Wireless Ground Monitoring:Enhanced safety in remote monitoring applicationsGuideline:Recommendation
Cable Routing:Avoid sharp bends; adhere to the minimum bend radiusInspection:Check regularly for signs of wear, damage, or deformation
Temperature Limits:Do not exceed rated operational temperaturesAspect:Recommendation
Packaging:Supplied on non-returnable reels for easy handlingStorage Temperature:Store in cool, dry conditions
Periodic Checks:Perform visual and electrical integrity inspections annually

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL VFD-BGC Power Cable: Advanced Portable Power Solution for Critical Industrial Applications

The ECKABEL VFD-BGC Power Cable is an advanced solution designed to meet the growing demands of modern industrial environments.

Specifically engineered for variable frequency drive (VFD) applications, this portable, shielded power cable ensures reliable performance, minimal interference, and maximum safety in harsh operating conditions.

1.1 Product Designation

Feature Details
Cable Type ECKABEL Brand Type VFD-BGC Power Cable
Voltage Rating 2000 Volts
Temperature Range Up to 90°C
Conductor Design Three-Conductor Design

1.2 Key Technological Innovations

Innovation Description
Ground-Check Conductor Specialized conductor minimizes failure risks and monitors integrity
EMI Shielding Advanced design reduces electromagnetic interference (EMI)
Mechanical Protection Enhanced system provides superior resistance to impact and abrasion

These technologies make the ECKABEL VFD-BGC Power Cable a preferred choice for industries dealing with high-EMI environments, VFD systems, and motor drive applications.


II. Technical Specifications

2.1 Conductor Characteristics

Property Details
Material Coated Annealed Copper
Conductor Size Range 2 AWG through 500 kcmil
Stranding Rope-lay stranded, ASTM B172-compliant
Ground-Check Design Extensible, high-flex conductor

The rope-lay-stranded copper conductors provide excellent flexibility and tensile strength, making the cable suitable for dynamic operations.


2.2 Insulation and Jacket

Insulation Feature Details
Material Ethylene Propylene Rubber (EPR)
Core Insulation High-strength polypropylene
Dielectric Strength Rated for 2000 volts
Jacket Property Details
Material Chlorinated Polyethylene (CPE)
Construction Two-layer, lead-cured, extra-heavy-duty
Resistance Properties Heat, moisture, oil, chemicals, and UV

The combination of EPR insulation and CPE jacket provides unmatched durability and dielectric performance, ensuring reliability even in corrosive or high-temperature environments.


2.3 Shielding Technology

Shielding Feature Details
Shield Type Flexible copper braid and aluminum tape
Transfer Impedance Low transfer impedance for EMI suppression
Symmetrical Grounding Prevents current imbalances

The cable's shielding ensures that sensitive VFD systems and connected motors operate without interference, boosting overall system reliability.


III. Performance Characteristics

3.1 Mechanical Durability

Resistance Type Advantage
Impact Withstands accidental drops and collisions
Abrasion Protects against wear from rough handling
Flame Meets stringent fire safety requirements
UV and Sunlight Ensures long-term outdoor performance

3.2 Electrical Performance

Electrical Feature Benefit
Common Mode Current Control Reduces harmonics for smoother motor operation
Noise Suppression Advanced EMI shielding minimizes signal disturbances
Ground Monitoring Provides fail-safe detection of ground faults

These features make the ECKABEL VFD-BGC Power Cable indispensable for high-performance motor connections and critical industrial systems.


IV. Compliance and Certification

Certification Standard
MSHA Approval Certified for mining safety
Flame Test Compliance Meets stringent flame resistance standards
Environmental Approvals Certified by the Pennsylvania Department of Environmental Protection

The ECKABEL VFD-BGC Power Cable complies with global industrial standards, ensuring safe and legal operation in critical environments.

ECKABEL VFD-BGC Power Cable: Advanced Portable Power Solution for Critical Industrial Applications 1


V. Recommended Applications

5.1 Primary Use Cases

Application Description
Mining Equipment Ideal for trailing cables in rugged underground settings
VFD Systems Optimized for PWM-driven variable frequency drives
Motor Interfaces Reliable connections in dynamic motor operations

5.2 Specialized Deployment Scenarios

Scenario Example Use Case
Inverter-to-Motor High-efficiency connections in EMI-heavy environments
Wireless Ground Monitoring Enhanced safety in remote monitoring applications

VI. Installation and Handling Guidelines

6.1 Best Practices

Guideline Recommendation
Cable Routing Avoid sharp bends; adhere to the minimum bend radius
Inspection Check regularly for signs of wear, damage, or deformation
Temperature Limits Do not exceed rated operational temperatures

 

 

6.2 Storage and Maintenance

Aspect Recommendation
Packaging Supplied on non-returnable reels for easy handling
Storage Temperature Store in cool, dry conditions
Periodic Checks Perform visual and electrical integrity inspections annually

VII. Technical Support and Additional Resources

ECKABEL offers a range of support services to help you select and optimize your cable for industrial applications:

  • Application Engineering Support for custom installations
  • Manufacturer Documentation for detailed specifications and compliance guidelines
  • Customization Options, including:
    • Color-coded jackets for easy identification
    • Special-length configurations tailored to project needs

Conclusion

The ECKABEL VFD-BGC Power Cable combines advanced shielding technology, durable materials, and compliance with international standards to deliver a superior solution for industrial power applications. Its performance in variable frequency drive systems and high-EMI environments makes it a valuable addition to any critical electrical infrastructure.

Contact ECKABEL Cable today to learn more about how this cutting-edge power cable can meet your industrial needs!


References and Standards:

  • ASTM B172: Specification for Rope-Lay-Stranded Copper Conductors
  • MSHA Electrical Safety Guidelines
  • IEEE Standards for Power Cable Applications in Industrial Environments

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat