ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems

Product Details

High quality ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
DIN VDE 0168 Mining Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: PROTOMONT SHOEU 0, ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mi, Black Color

Color:BlackHigh Voltage Capacity:Voltage Resilience For Mining
Tensile Strength:30kNRated Voltage:600V
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:PROTOMONT (M) (N)SHOEU Payment & Shipping Terms
Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Armor Material:Galvanized SteelVersatile Compatibility:Fits Various Equipment Configurations
Custom Power Solutions:Tailored For Equipment NeedsResistant To Debris:Guards Against Mining Debris
Voltage:600V / 1000VDurable Construction:Long-lasting In Demanding Conditions
Shielding Material:Tinned Copper BraidMaximum Tensile Strength:20kN
Armoring Material:Galvanized Steel WiresReliable Performance:Ensures A Long Operational Life
Parameter:SpecificationRated Voltage:450/750 V (control cables)
Maximum Operating Voltage (AC):0.7/1.2 kVMaximum Operating Voltage (DC):0.9/1.8 kV
AC Test Voltage:3 kV (power cables)Temperature Range:Fixed: -40°C to 80°C
Conductor Material:Electrolytic copper, finely stranded (Class 5)Insulation Material:PROTOLON EPR
Environmental Factor:PerformanceTemperature Tolerance:Operates between -40°C and 80°C
Water Resistance:Submersible up to 500 metersOzone and UV Resistance:Fully resistant to degradation
Oil Resistance:Complies with EN 60811-404Mechanical Parameter:Specification
Rewinding Speed:Up to 100 m/minTensile Load on Conductor:Up to 15 N/mm²
Torsional Stress:Up to 100° per meterBending Radius:Meets DIN VDE 0298 part 3 standards
Certification/Standard:DetailsRussian Federation Fire Certificate:Certified for safety in hazardous environments.
TR-Zertifikat:Ensures performance reliability in extreme applications.GOST K and GOST B:Meets stringent Russian industrial standards.
DIN VDE 0250 Part 812:Fully compliant with international cable standards.Feature:ECKABEL PROTOMONT (M) (N)SHOEU
Flexibility:Superior, designed for dynamic environmentsEnvironmental Resistance:Ozone, water, UV, and oil resistant
Operational Temperature:-40°C to 80°CService Life:Extended due to advanced materials

Payment & Shipping Terms

Minimum Order Quantity:200 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables: Advanced Solutions for Opencast Mining Electrical Systems

The ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV cables are designed to revolutionize electrical systems in demanding opencast mining environments. These cables boast unmatched durability, flexibility, and reliability, specifically tailored for dynamic and challenging industrial conditions.

Engineered with advanced materials and precision manufacturing techniques, they provide long-lasting performance even under extreme operational stresses.


Product Overview

Key Technical Specifications

Parameter Specification
Rated Voltage 450/750 V (control cables)
  0.6/1 kV (power cables)
Maximum Operating Voltage (AC) 0.7/1.2 kV
Maximum Operating Voltage (DC) 0.9/1.8 kV
AC Test Voltage 3 kV (power cables)
  2 kV (control cables)
Temperature Range Fixed: -40°C to 80°C
  Fully flexible: -25°C to 60°C
Conductor Material Electrolytic copper, finely stranded (Class 5)
Insulation Material PROTOLON EPR

 

 

 

Design Features

  • Conductor: Electrolytic copper, finely stranded for enhanced flexibility and electrical conductivity.
  • Insulation: Ethylene Propylene Rubber (EPR), ensuring exceptional dielectric strength and environmental resistance.
  • Core Identification: Light gray insulation with black numerical markings, enabling easy identification during installation.
  • Sheathing: Inner sheath made of special EPR compound, with an outer sheath of black chlorinated rubber (5GM3) for maximum protection.

Operational Capabilities

Environmental Resistance

Environmental Factor Performance
Temperature Tolerance Operates between -40°C and 80°C
Water Resistance Submersible up to 500 meters
Ozone and UV Resistance Fully resistant to degradation
Oil Resistance Complies with EN 60811-404

Mechanical Performance

Mechanical Parameter Specification
Rewinding Speed Up to 100 m/min
Tensile Load on Conductor Up to 15 N/mm²
Torsional Stress Up to 100° per meter
Bending Radius Meets DIN VDE 0298 part 3 standards

 

 

Specialized Applications

The PROTOMONT (M) (N)SHOEU cables excel in diverse opencast mining and industrial environments.

Primary Use Cases

  • Conveyor Belt Electrical Systems: Provides stable power and control for continuous belt operations.
  • Movable Equipment Installations: Designed to handle repetitive movement without compromising performance.
  • Submersible Pump Connections: Reliable in deep-water applications up to 500 meters.
  • Interconnected Mobile Units: Facilitates safe and efficient energy transfer between machinery.

ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems 1

Deployment in Harsh Conditions

  • Temperature Extremes: Withstands both freezing and high-temperature conditions without degradation.
  • High-Stress Motion: Retains flexibility and durability under constant bending, twisting, and pulling.

Compliance and Certifications

Certification/Standard Details
Russian Federation Fire Certificate Certified for safety in hazardous environments.
TR-Zertifikat Ensures performance reliability in extreme applications.
GOST K and GOST B Meets stringent Russian industrial standards.
DIN VDE 0250 Part 812 Fully compliant with international cable standards.

Unique Selling Points

Problems Solved

  • Mechanical Stress Tolerance: Withstands high tension, torsion, and dynamic movement in demanding operations.
  • Environmental Durability: Resists water ingress, oil, UV, ozone, and extreme temperatures.
  • Electrical Reliability: Maintains consistent power delivery and signal transmission even under varying load conditions.

Advantages of Materials and Manufacturing

  • Advanced Sheathing Materials: Chlorinated rubber and EPR compounds offer unmatched environmental resistance.
  • Flexible Conductor Design: The finely stranded Class 5 copper allows for superior flexibility and energy efficiency.
  • Rigorous Quality Testing: Each cable undergoes extensive testing to ensure long-term reliability and safety.

ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV Cables Advanced Solutions for Opencast Mining Electrical Systems 2

 

 

Installation Considerations

Best Practices

Submersion Depth: Limit to 500 meters for optimal performance.

Cable Management: Use appropriate support systems to reduce mechanical strain.

Inspection Schedule: Regularly check for visible wear and electrical continuity.

Installation Environment: Avoid sharp bends and ensure compliance with bending radius specifications.

Tips for Extending Lifespan

  • Use protective conduits in areas of high abrasion.
  • Avoid exceeding tensile load and torsional stress limits.
  • Implement proper termination techniques to reduce strain on connectors.

Comparative Advantages

Feature ECKABEL PROTOMONT (M) (N)SHOEU Standard Mining Cables
Flexibility Superior, designed for dynamic environments Moderate
Environmental Resistance Ozone, water, UV, and oil resistant Limited
Operational Temperature -40°C to 80°C -20°C to 70°C
Service Life Extended due to advanced materials Standard

Conclusion

The ECKABEL PROTOMONT (M) (N)SHOEU 0.6/1kV cables redefine standards for electrical systems in opencast mining and industrial applications.

By integrating cutting-edge materials, innovative design, and robust safety features, they ensure unparalleled performance and durability in the harshest environments.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat