ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications

Product Details

High quality ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
DIN VDE 0250 Reeling Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: SUPROMONT 3GHSSYCY, Flexible Cable, ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critic

Shielding Coverage:100%Abrasion Resistance:Withstands Wear And Tear
Optimized For Quarrying:Designed For Quarrying ApplicationsTailored For Handling:Enhances Material Handling Efficiency
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 814Model Number:SUPROMONT (N)3GHSSYCY Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Insulation:Special MaterialMaterial Stockpiling:Efficient Stockyard Management
Severe Conditions:Thrives In Harsh EnvironmentsMaterial Reclaiming:Ensures Effective Retrieval
Efficient Reclaiming:Enhances Material RetrievalShielding:Unshielded
High Flexibility:Adaptable In Dynamic EnvironmentsJacket Material:Neoprene
Highly Resilient:Endures Challenging ConditionsBulk Handling System:Streamlines Material Handling
Parameter:SpecificationRated Voltage:3.6/6 kV
Maximum AC Operating Voltage:4.2/7.2 kVMaximum DC Operating Voltage:5.4/10.8 kV
AC Test Voltage:11 kVMaximum Conductor Temp:90°C
Short Circuit Temp Tolerance:250°COperating Temp Range:- Fixed Installation: -40°C to +80°C
Layer:Material/DetailsConductor:Finely stranded copper
Insulation:PROTOLON (EPR compound)Intermediate Sheath:PVC-based DMV6 compound
Reinforcement:Galvanized steel wire braidOuter Sheath:Red PVC-based DMV6 compound
Challenge:Mitigation StrategyEnvironmental wear in harsh conditions:Use protective coatings and regular maintenance
Electrical field instability:Leverage advanced semiconductive layersMechanical damage:Implement proper routing and secure fastening

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications

The ECKABEL SUPROMONT (N)3GHSSYCY is an advanced medium-voltage flexible cable, expertly engineered to meet the rigorous demands of underground and industrial power systems.

It delivers unmatched reliability and adaptability in harsh environments, making it an essential component for power distribution in underground mining, tunnel construction, and other critical applications.

  • Brand: ECKABEL SUPROMONT
  • Type Designation: (N)3GHSSYCY
  • Standardization: Fully compliant with DIN VDE 0250 part 605
  • Certification: VDE Certificate of Conformity

Primary Application Domains

The SUPROMONT (N)3GHSSYCY excels in environments where robustness, flexibility, and safety are non-negotiable. Key domains include:

  • Underground mining installations requiring durable, flexible power supply cables.
  • Tunnel site power systems that demand resistance to mechanical stress and harsh conditions.
  • Movable medium-voltage equipment, including mobile transformers.
  • Specialized industrial settings where high-reliability cables are necessary.

Technical Specifications

Electrical Characteristics

Parameter Specification
Rated Voltage 3.6/6 kV
Maximum AC Operating Voltage 4.2/7.2 kV
Maximum DC Operating Voltage 5.4/10.8 kV
AC Test Voltage 11 kV

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications 1

 

 

Conductor Engineering

The conductor design ensures maximum efficiency and safety.

  • Material: Finely stranded untinned copper (Class 5).
  • Configuration:
    • Three main cores with concentrically laid PE conductors.
    • Control core in each outer interstice for enhanced monitoring.
    • Advanced semiconductive layers for precise electrical field control.

 

Insulation and Protective Features

The SUPROMONT cable uses PROTOLON (EPR-based) insulation, providing superior thermal and electrical performance.

  • Inner and outer semiconductive layers enhance protection against electrical field stress.
  • Specialized 6kV-grade outer semiconductive layer for added safety.

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications 2

 

Performance Capabilities

Thermal Resistance

Parameter Specification
Maximum Conductor Temp 90°C
Short Circuit Temp Tolerance 250°C
Operating Temp Range - Fixed Installation: -40°C to +80°C

 

Environmental Resilience

  • Fire Resistance: Meets EN 60332-1-2 and IEC 60332-1-2 standards.
  • Weather Resistance:
    • Resilient to ozone and moisture damage.
    • Suitable for unrestricted indoor and underground use.

Mechanical Durability

Designed to handle high mechanical stress:

  • Maximum Tensile Load: 15 N/mm².
  • Bending Radius: Meets DIN VDE 0298 part 3 specifications.

 

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications 3

 

Structural Composition

Cable Layer Construction

Layer Material/Details
Conductor Finely stranded copper
Insulation PROTOLON (EPR compound)
Intermediate Sheath PVC-based DMV6 compound
Reinforcement Galvanized steel wire braid
Outer Sheath Red PVC-based DMV6 compound

Monitoring and Safety Features

The cable includes built-in monitoring mechanisms:

  • Conductive tape for enhanced field stability.
  • Overall concentric copper wire spinning for uniform load distribution.

Core Identification:

  • Main Cores: Natural color with a black semiconductive layer.
  • Control Cores: Black with white numerical markings for easy identification.

ECKABEL SUPROMONT (N)3GHSSYCY: Advanced Medium-Voltage Flexible Cable for Critical Underground Applications 4

 

 

Professional Considerations and Application Guidance

Critical Selection Criteria

When selecting SUPROMONT (N)3GHSSYCY, consider the following:

  1. Ensure compatibility with specific underground equipment.
  2. Install according to DIN VDE guidelines for maximum performance and safety.
  3. Regularly inspect for mechanical stress and wear.

Potential Challenges and Mitigation

Challenge Mitigation Strategy
Environmental wear in harsh conditions Use protective coatings and regular maintenance
Electrical field instability Leverage advanced semiconductive layers
Mechanical damage Implement proper routing and secure fastening

 

Compliance and Quality Assurance

The SUPROMONT (N)3GHSSYCY is backed by rigorous quality standards:

  • Fully certified by VDE for medium-voltage applications.
  • Tested to meet international standards, ensuring reliability in critical infrastructures.
  • ECKABEL offers complete traceability and documentation to maintain operational integrity.

Conclusion

The ECKABEL SUPROMONT (N)3GHSSYCY is a state-of-the-art solution for medium-voltage flexible cables in demanding underground and industrial environments.

Its robust design, advanced materials, and compliance with international standards make it an unmatched choice for critical power distribution needs.


Recommended Next Steps

  1. Consult with ECKABEL experts to determine the best configuration for your needs.
  2. Request a technical datasheet for in-depth specifications.
  3. Plan a site-specific assessment to ensure compatibility and performance.

Note: Always collaborate with a qualified electrical engineer to ensure proper installation and safety in all applications.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote
WhatsApp QR code Contact us on WhatsApp WeChat QR code Contact us on WeChat