Highlight: TSCGEW U 3, Reeling Drum Cable, Type R-(N)TSCGEWÖU 3.6/6 To 18/30 KV Medium Voltage Reeling Drum Cable For Indus
| Bulk Cargo Conveyor: | Facilitates Cargo Transport | Shielding Coverage: | 100% |
| Cable Temperature: | 105℃ | Material Reclaiming: | Ensures Effective Retrieval |
| Place of Origin: | Hefei HONGKONG China | Brand Name: | ECKABEL™ |
| Certification: | VDE 0250 Part 813 | Model Number: | Reeling Cable Payment & Shipping Terms |
| Minimum Order Quantity: | 800 Meter | Packaging Details: | Cable Reels or Packaging Bags |
| Delivery Time: | 15-30 Work Day | Payment Terms: | T/T, Western Union |
| Seamless Stacking: | Optimizes Material Stacking | Temperature Rating: | -40°C To 90°C |
| Flexibility: | Highly Flexible | Severe Conditions: | Thrives In Harsh Environments |
| Feature: | Specification | Voltage Range: | 3.6/6 to 18/30 kV |
| Cable Type: | R-(N)TSCGEWÖU | Application: | Reeling Drum Cable |
| Conductor Material: | Stranded Copper | Insulation Material: | EPR (Ethylene Propylene Rubber) |
| Sheath Material: | PUR (Polyurethane) | Temperature Range: | -40°C to +90°C |
| Weather Resistance: | Excellent | Oil Resistance: | High |
| Standards Compliance: | IEC, UL, DNV GL, ABS | Number of cores Cross-section: | Conductor diameter |
| Approximate overall diameter: | Approximate weight | Conductor resistance at 200C: | Current-currying capacity at 300C |
| mm2: | mm | mm: | kg/km |
| Ω/km: | A | 3x25+3x16/3: | 6.60 |
| 39.9: | 2414 | 0.795: | 132 |
| 3x25+3x25/3: | 6.60 | 39.9: | 2486 |
| 3x25+3x50/3: | 6.60 | 39.9: | 2666 |
| 3x35+3x25/3: | 7.30 | 41.5: | 2860 |
| 0.565: | 161 | 3x35+3x50/3: | 7.30 |
| 41.5: | 3042 | 3x50+3x25/3: | 9.30 |
| 45.8: | 3561 | 0.393: | 202 |
| 3x50+3x50/3: | 9.30 | 45.8: | 3747 |
| 3x70+3x35/3: | 11.10 | 49.1: | 4420 |
| 0.277: | 251 | 3x70+3x50/3: | 11.10 |
| 49.1: | 4688 | 3x95+3x50/3: | 13.30 |
| 56.2: | 5780 | 0.210: | 301 |
| 3x120+3x70/3: | 14.40 | 58.4: | 6800 |
| 0.164: | 351 | 3x150+3x70/3: | 16.30 |
| 64.5: | 8231 | 0.132: | 405 |
| 3x185+3x95/3: | 18.50 | 69.3: | 9711 |
| 0.108: | 462 | 3x240+3x120/3: | 19.80 |
| 72.6: | 11733 | 0.0817: | 540 |
| 41.6: | 2640 | 41.6: | 2821 |
| 43.2: | 3018 | 43.2: | 3200 |
| 47.5: | 3735 | 47.5: | 3922 |
| 52.6: | 4839 | 52.6: | 4943 |
| 58.0: | 5995 | 60.1: | 7023 |
| 66.2: | 8478 | 71.0: | 9975 |
| 76.1: | 12339 | 3x300+3x150/3: | 23.80 |
| 84.1: | 15031 | 0.0654: | 620 |
| 45.1: | 2972 | 0.795: | 138 |
| 45.1: | 3153 | 46.7: | 3363 |
| 0.565: | 173 | 46.7: | 3544 |
| 52.8: | 4338 | 0.393: | 216 |
| 52.8: | 4525 | 56.0: | 5249 |
| 0.277: | 265 | 56.0: | 5359 |
| 63.2: | 6723 | 0.210: | 320 |
| 65.4: | 7777 | 0.164: | 370 |
| 69.7: | 8997 | 0.132: | 428 |
| 76.2: | 10860 | 0.108: | 489 |
| 79.6: | 12934 | 0.0817: | 574 |
| 48.1: | 3282 | 48.1: | 3469 |
| 51.5: | 3905 | 51.5: | 4091 |
| 55.8: | 4707 | 55.8: | 4888 |
| 59.0: | 5632 | 59.0: | 5743 |
| 66.2: | 7155 | 68.4: | 8230 |
| 72.7: | 9471 | 79.2: | 11377 |
| 82.6: | 13474 | 57.6: | 3945 |
| 57.6: | 4125 | 59.3: | 4367 |
| 59.3: | 4554 | 65.4: | 5199 |
| 65.4: | 5386 | 68.6: | 6437 |
| 68.6: | 6547 | 75.8: | 7744 |
| 77.9: | 8897 | 82.3: | 10453 |
| 88.8: | 12078 | 92.1: | 14584 |
| Un aged test pieces: | Tensile strength min. 6 N/mm2 | Ageing in air oven: | 1350C, 168 h |
| Un aged test pieces: | Tensile strength min. 10 N/mm2 | Ageing in air oven: | 1000C, 168 h |
| After ageing in oil: | 1000C, 24 h | Un aged test pieces: | Tensile strength min. 15 N/mm2 |
| Tear resistance: | Value of min. 30 N/mm | Resistance to oil: | DIN VDE, part 811-2-1 p. 10 |
| Weather resistance: | resistant to ozone, UV and moisture | Feature: | R-(N)TSCGEWÖU Cable |
| Stationary Medium Voltage Cable: | Low Voltage Cable | 0.6/1 to 12/20 kV: | 0.6/1 kV |
| Application: | Reeling, Flexible | Stationary: | Stationary |
| Moderate: | Moderate | Flexibility: | High |
| Low: | Moderate | Ideal for Movement: | Yes |
| No: | No | Cable Temperature: | 105\u2103 |
Payment & Shipping Terms
| Minimum Order Quantity: | 800 Meter | Packaging Details: | Cable Reels or Packaging Bags |
| Delivery Time: | 15-30 Work Day | Payment Terms: | T/T, Western Union |
Type R-(N)TSCGEWÖU 3.6/6 To 18/30 KV Medium Voltage Reeling Drum Cable For Industrial Port Machinery Drum
For industries that rely on high-performance port machinery, the durability and reliability of their cables are crucial. The Type R-(N)TSCGEWÖU 3.6/6 to 18/30 kV Medium Voltage Reeling Drum Cable stands out as a powerful solution designed specifically for industrial port machinery, including harbor cranes, ship-to-shore cranes, and quayside equipment.
This medium voltage reeling drum cable not only provides efficient power but also withstands harsh environmental conditions to ensure continuous operation of heavy-duty equipment in port environments.
This article explores the key features, specifications, and applications of the R-(N)TSCGEWÖU reeling drum cable, along with comparison tables and in-depth insights into its suitability for industrial port use.

Overview of R-(N)TSCGEWÖU 3.6/6 to 18/30 kV Reeling Drum Cable
R-(N)TSCGEWÖU cables are highly specialized medium voltage cables with voltage ratings from 3.6/6 kV to 18/30 kV, making them ideal for powering large-scale machinery used in ports and industrial applications.
Their unique structure and material composition ensure flexibility, durability, and resistance to extreme weather conditions, oil, and flames.
Application Scenarios
The Type R-(N)TSCGEWÖU Medium Voltage Reeling Drum Cable is specifically designed for use in industrial port machinery drums. It is engineered to meet the demanding needs of high-voltage applications in challenging environments.
Industrial Port Machinery: Ideal for cranes, hoists, and other heavy machinery used in ports. The cable can handle the mechanical stress of continuous reeling and unreeling.
Material Handling Systems: Suitable for use in conveyor systems, ensuring reliable power transmission in dynamic and moving equipment.
Harsh Environmental Conditions: Designed to withstand exposure to saltwater, chemicals, and extreme temperatures, making it perfect for port environments.
Mobile Equipment: Provides dependable power for mobile machinery that requires frequent movement and reeling, ensuring operational efficiency.
Harbor Crane Cable: For heavy-duty harbor cranes, this medium voltage reeling drum cable provides a consistent and reliable power supply that meets the demands of large lifting operations.
Ship-to-Shore Crane Cable: With the flexibility to endure constant movement and reeling, these cables are ideal for connecting ship-to-shore cranes.
Quayside Crane Cable: In the harsh conditions on the quayside, this cable’s weatherproof and oil-resistant properties ensure it can withstand marine environments and exposure to corrosive elements.
Port Equipment Cable: From container handlers to other essential port equipment, this cable meets the power and durability requirements to keep equipment running smoothly.
Offshore Platform Cable: For offshore applications, the cable’s weatherproof and flame-retardant features provide safety and durability in remote, demanding environments.
Why Choose Type R-(N)TSCGEWÖU Reeling Drum Cable?
Choosing the right reeling drum cable is essential for industrial port machinery that requires a cable capable of handling constant movement, tension, and harsh environments. Type R-(N)TSCGEWÖU cables offer:
Flexibility and Strength: With enhanced flexibility, these cables are perfect for reeling applications where they experience continuous motion.
Durability: Built to last, this medium voltage cable withstands rough handling, extreme temperatures, and exposure to oil and chemicals.
Safety: Features like flame retardant properties and low smoke zero halogen (LSZH) insulation ensure both equipment safety and personnel protection.
Versatility: Suitable for a range of applications including harbor cranes, quayside machinery, offshore platforms, and other port equipment.
Key Features and Benefits
Voltage Rating and Flexibility
Medium Voltage Range: From 3.6/6 to 18/30 kV, these cables support medium voltage needs for powerful machinery.
Flexible Medium Voltage Cable: The high flexibility of the cable allows it to perform well in reeling applications where continuous movement and bending are necessary.
Enhanced Durability for Port Conditions
Weatherproof Cable: Designed to withstand extreme temperatures, high humidity, and direct exposure to sunlight, making it ideal for outdoor applications.
Oil-Resistant Cable: With a special oil-resistant outer jacket, this cable can withstand exposure to oils and chemicals commonly found in industrial environments.
Safety Features
Flame Retardant Cable: Minimizes the risk of fire, which is especially important in port areas with large amounts of flammable cargo and materials.
Low Smoke Zero Halogen (LSZH) Cable: Reduces toxic emissions, ensuring a safer environment in the event of a fire.
Technical Specifications
| Feature | Specification |
|---|---|
| Voltage Range | 3.6/6 to 18/30 kV |
| Cable Type | R-(N)TSCGEWÖU |
| Application | Reeling Drum Cable |
| Conductor Material | Stranded Copper |
| Insulation Material | EPR (Ethylene Propylene Rubber) |
| Sheath Material | PUR (Polyurethane) |
| Temperature Range | -40°C to +90°C |
| Weather Resistance | Excellent |
| Oil Resistance | High |
| Standards Compliance | IEC, UL, DNV GL, ABS |
These specifications highlight the rugged construction and technical robustness of the R-(N)TSCGEWÖU cable, making it highly suitable for applications in industrial port machinery.
Enhanced Durability: Built to withstand the rigors of industrial use, reducing the need for frequent replacements.
Operational Efficiency: High flexibility and resistance to mechanical stress ensure smooth and efficient reeling operations.
Safety Compliance: Adherence to international standards reduces risks and ensures safe operation.
Versatility: Suitable for a wide range of applications in industrial port machinery and material handling systems.
Flame retardant
Temperature range -25℃ to +90℃. For fixed installation lowest temperature is -40℃
UV, sunlight, ozone and oil resistant
Embossing marking for easy identification







-
Conductor:Annealed flexible stranded tin coated or bare copper class 5 to IEC 60228, HD 383
-
Insulation:Ethylene-propylene rubber (EPR) type 3GI3 to DIN VDE 0207 part 20
-
Separator:If needed a suitable tape separator between the conductor and insulation
-
Conductor screen:Semi-conductive layer
-
Insulation screen:Semi-conductive layer max. resistivity of semi-conductive layers - 200 Ω x m
-
Internal layer of sheath:A synthetic thermosetting compound type 5GM3 in accordance to DIN VDE 0207 part 21
-
Antitorsion braid:Braid of polyamide threads between internal and outer layer of sheath
-
Outer layer of sheath:A synthetic thermosetting compound type 5GM5 or 5GM3 to DIN VDE 0207 part 21
-
Colour of outer jacket:Red or other colours can be provided
-
Standard marking:HT Cables R-(N)TSCGEWÖU (Size) (Voltage) (Year)
| Number of cores Cross-section | Conductor diameter | Approximate overall diameter | Approximate weight | Conductor resistance at 200C | Current-currying capacity at 300C |
| mm2 | mm | mm | kg/km | Ω/km | A |
| 3.6/6 kV R-(N)TSCGEWÖU | |||||
| 3x25+3x16/3 | 6.60 | 39.9 | 2414 | 0.795 | 132 |
| 3x25+3x25/3 | 6.60 | 39.9 | 2486 | 0.795 | 132 |
| 3x25+3x50/3 | 6.60 | 39.9 | 2666 | 0.795 | 132 |
| 3x35+3x25/3 | 7.30 | 41.5 | 2860 | 0.565 | 161 |
| 3x35+3x50/3 | 7.30 | 41.5 | 3042 | 0.565 | 161 |
| 3x50+3x25/3 | 9.30 | 45.8 | 3561 | 0.393 | 202 |
| 3x50+3x50/3 | 9.30 | 45.8 | 3747 | 0.393 | 202 |
| 3x70+3x35/3 | 11.10 | 49.1 | 4420 | 0.277 | 251 |
| 3x70+3x50/3 | 11.10 | 49.1 | 4688 | 0.277 | 251 |
| 3x95+3x50/3 | 13.30 | 56.2 | 5780 | 0.210 | 301 |
| 3x120+3x70/3 | 14.40 | 58.4 | 6800 | 0.164 | 351 |
| 3x150+3x70/3 | 16.30 | 64.5 | 8231 | 0.132 | 405 |
| 3x185+3x95/3 | 18.50 | 69.3 | 9711 | 0.108 | 462 |
| 3x240+3x120/3 | 19.80 | 72.6 | 11733 | 0.0817 | 540 |
| 6/10 kV R-(N)TSCGEWÖU | |||||
| 3x25+3x25/3 | 6.60 | 41.6 | 2640 | 0.795 | 132 |
| 3x25+3x50/3 | 6.60 | 41.6 | 2821 | 0.795 | 132 |
| 3x35+3x25/3 | 7.30 | 43.2 | 3018 | 0.565 | 161 |
| 3x35+3x50/3 | 7.30 | 43.2 | 3200 | 0.565 | 161 |
| 3x50+3x25/3 | 9.30 | 47.5 | 3735 | 0.393 | 202 |
| 3x50+3x50/3 | 9.30 | 47.5 | 3922 | 0.393 | 202 |
| 3x70+3x35/3 | 11.10 | 52.6 | 4839 | 0.277 | 251 |
| 3x70+3x50/3 | 11.10 | 52.6 | 4943 | 0.277 | 251 |
| 3x95+3x50/3 | 13.30 | 58.0 | 5995 | 0.210 | 301 |
| 3x120+3x70/3 | 14.40 | 60.1 | 7023 | 0.164 | 351 |
| 3x150+3x70/3 | 16.30 | 66.2 | 8478 | 0.132 | 405 |
| 3x185+3x95/3 | 18.50 | 71.0 | 9975 | 0.108 | 462 |
| 3x240+3x120/3 | 19.80 | 76.1 | 12339 | 0.0817 | 540 |
| 3x300+3x150/3 | 23.80 | 84.1 | 15031 | 0.0654 | 620 |
| 8.7/15 kV R-(N)TSCGEWÖU | |||||
| 3x25+3x25/3 | 6.60 | 45.1 | 2972 | 0.795 | 138 |
| 3x25+3x50/3 | 6.60 | 45.1 | 3153 | 0.795 | 138 |
| 3x35+3x25/3 | 7.30 | 46.7 | 3363 | 0.565 | 173 |
| 3x35+3x50/3 | 7.30 | 46.7 | 3544 | 0.565 | 173 |
| 3x50+3x25/3 | 9.30 | 52.8 | 4338 | 0.393 | 216 |
| 3x50+3x50/3 | 9.30 | 52.8 | 4525 | 0.393 | 216 |
| 3x70+3x35/3 | 11.10 | 56.0 | 5249 | 0.277 | 265 |
| 3x70+3x50/3 | 11.10 | 56.0 | 5359 | 0.277 | 265 |
| 3x95+3x50/3 | 13.30 | 63.2 | 6723 | 0.210 | 320 |
| 3x120+3x70/3 | 14.40 | 65.4 | 7777 | 0.164 | 370 |
| 3x150+3x70/3 | 16.30 | 69.7 | 8997 | 0.132 | 428 |
| 3x185+3x95/3 | 18.50 | 76.2 | 10860 | 0.108 | 489 |
| 3x240+3x120/3 | 19.80 | 79.6 | 12934 | 0.0817 | 574 |
| 12/20 kV R-(N)TSCGEWÖU | |||||
| 3x25+3x25/3 | 6.60 | 48.1 | 3282 | 0.795 | 138 |
| 3x25+3x50/3 | 6.60 | 48.1 | 3469 | 0.795 | 138 |
| 3x35+3x25/3 | 7.30 | 51.5 | 3905 | 0.565 | 173 |
| 3x35+3x50/3 | 7.30 | 51.5 | 4091 | 0.565 | 173 |
| 3x50+3x25/3 | 9.30 | 55.8 | 4707 | 0.393 | 216 |
| 3x50+3x50/3 | 9.30 | 55.8 | 4888 | 0.393 | 216 |
| 3x70+3x35/3 | 11.10 | 59.0 | 5632 | 0.277 | 265 |
| 3x70+3x50/3 | 11.10 | 59.0 | 5743 | 0.277 | 265 |
| 3x95+3x50/3 | 13.30 | 66.2 | 7155 | 0.210 | 320 |
| 3x120+3x70/3 | 14.40 | 68.4 | 8230 | 0.164 | 370 |
| 3x150+3x70/3 | 16.30 | 72.7 | 9471 | 0.132 | 428 |
| 3x185+3x95/3 | 18.50 | 79.2 | 11377 | 0.108 | 489 |
| 3x240+3x120/3 | 19.80 | 82.6 | 13474 | 0.0817 | 574 |
| 18/30 kV R-(N)TSCGEWÖU | |||||
| 3x25+3x25/3 | 6.60 | 57.6 | 3945 | 0.795 | 138 |
| 3x25+3x50/3 | 6.60 | 57.6 | 4125 | 0.795 | 138 |
| 3x35+3x25/3 | 7.30 | 59.3 | 4367 | 0.565 | 173 |
| 3x35+3x50/3 | 7.30 | 59.3 | 4554 | 0.565 | 173 |
| 3x50+3x25/3 | 9.30 | 65.4 | 5199 | 0.393 | 216 |
| 3x50+3x50/3 | 9.30 | 65.4 | 5386 | 0.393 | 216 |
| 3x70+3x35/3 | 11.10 | 68.6 | 6437 | 0.277 | 265 |
| 3x70+3x50/3 | 11.10 | 68.6 | 6547 | 0.277 | 265 |
| 3x95+3x50/3 | 13.30 | 75.8 | 7744 | 0.210 | 320 |
| 3x120+3x70/3 | 14.40 | 77.9 | 8897 | 0.164 | 370 |
| 3x150+3x70/3 | 16.30 | 82.3 | 10453 | 0.132 | 428 |
| 3x185+3x95/3 | 18.50 | 88.8 | 12078 | 0.108 | 489 |
| 3x240+3x120/3 | 19.80 | 92.1 | 14584 | 0.0817 | 574 |
| PHYSICAL PARAMETERS | |
| Insulation | |
| Tensile tests for insulation shall value as follows: | |
Un aged test pieces |
Tensile strength min. 6 N/mm2 |
| Elongation at break min. 200% | |
Ageing in air oven |
1350C, 168 h |
| Change TS +/- 30% | |
| Change EB +/- 30% | |
| Internal sheath | |
| Tensile tests shall value as follows: | |
Un aged test pieces |
Tensile strength min. 10 N/mm2 |
| Elongation at break min. 300% | |
Ageing in air oven |
1000C, 168 h |
| Change TS +/- 30%, EB +/- 40% | |
After ageing in oil |
1000C, 24 h |
| Change TS and EB +/- 40% | |
| Outer sheath | |
| Tensile tests shall value as follows: | |
Un aged test pieces |
Tensile strength min. 15 N/mm2 |
| Elongation at break min. 300% | |
Ageing in air oven |
1000C, 168 h |
| Change TS +/- 30%, EB +/-40% | |
After ageing in oil |
1000C, 24 h |
| Change TS and EB +/- 40% | |
| Tear resistance | Value of min. 30 N/mm |
| CHEMICAL PARAMETERS | |
| Resistance to oil | DIN VDE, part 811-2-1 p. 10 |
| Weather resistance | resistant to ozone, UV and moisture |
RFQ: Common Questions and Answers
Q1: What are the key features of the Type R-(N)TSCGEWÖU Medium Voltage Reeling Drum Cable?
A1: This cable offers several important features:
- High Voltage Range: Suitable for medium voltage applications from 3.6/6 KV to 18/30 KV.
- Durability: Constructed with robust materials to endure high mechanical stress and frequent reeling.
- Flexibility: Maintains flexibility even in low temperatures, ensuring ease of use in various conditions.
- Chemical Resistance: Resistant to oils, acids, and alkalis, making it ideal for harsh industrial environments.
Q2: How does this cable ensure safety and reliability in port operations?
A2: Safety and reliability are ensured through:
- High Insulation Quality: Uses top-grade insulation materials to prevent electrical faults and ensure consistent power delivery.
- Flame Retardant: Meets IEC 60332-1 standards for flame retardancy, reducing fire risks.
Q3: What standards does the Type R-(N)TSCGEWÖU cable meet?
A3: This cable meets several critical standards:
- IEC 60228: For conductor specifications.
- IEC 60332-1: For flame retardant properties.
- IEC 60840: For power cables with extruded insulation and their accessories for rated voltages above 30 KV.
- ISO 9001: Certified manufacturing processes ensure consistent quality.
Q4: Can this cable be customized for specific industrial needs?
A4: Yes, customization options include:
- Length: Available in various lengths to suit different operational needs.
- Conductor Size: Different conductor sizes can be selected based on the power requirements.
- Sheath Material: Options for different sheath materials to provide additional protection against specific environmental factors.
The Type R-(N)TSCGEWÖU Medium Voltage Reeling Drum Cable is a reliable and robust solution for industrial port machinery. Its durable construction, flexibility, and adherence to safety standards make it an excellent choice for high-voltage applications in demanding environments.
Whether used in cranes, hoists, or other heavy-duty equipment, this cable ensures consistent performance and operational efficiency, making it an invaluable asset for any industrial port operation.
Comparison: R-(N)TSCGEWÖU Cable vs. Other Cable Types
| Feature | R-(N)TSCGEWÖU Cable | Stationary Medium Voltage Cable | Low Voltage Cable |
|---|---|---|---|
| Voltage Range | 3.6/6 to 18/30 kV | 0.6/1 to 12/20 kV | 0.6/1 kV |
| Application | Reeling, Flexible | Stationary | Stationary |
| Oil Resistance | High | Moderate | Moderate |
| Weather Resistance | Excellent | Moderate | Moderate |
| Flexibility | High | Low | Moderate |
| Ideal for Movement | Yes | No | No |
This comparison demonstrates the unique advantages of R-(N)TSCGEWÖU cables over other types, particularly in environments that require flexibility, movement, and durability.
Certifications and Standards
IEC Certified Cable: Our R-(N)TSCGEWÖU reeling drum cables comply with IEC standards, ensuring they meet international quality and safety criteria.
UL Listed Cable: This certification confirms the cable’s safety and suitability for use in industrial environments.
DNV GL Approved Cable: Suitable for marine and offshore applications, our cables are DNV GL approved, ensuring reliability and safety for offshore platforms.
ABS Approved Cable: Meeting the American Bureau of Shipping standards, these cables are ideal for both port and offshore environments, where reliability and safety are paramount.
Installation Tips for R-(N)TSCGEWÖU Reeling Drum Cable
Proper installation is key to maximizing the performance and longevity of your medium voltage reeling drum cable. Here are some guidelines:
Check Cable Compatibility: Ensure that the cable’s specifications match the machinery requirements.
Observe Bending Radius: The high flexibility of R-(N)TSCGEWÖU cables allows for tighter bending, but following recommended bending guidelines will enhance cable life.
Secure the Cable Properly: Use suitable cable grips and guides to prevent excessive strain during operation.
Routine Inspection: Regular inspections will help identify any signs of wear and tear before they escalate.
Frequently Asked Questions
Q1: What makes the R-(N)TSCGEWÖU cable ideal for industrial port machinery?
The R-(N)TSCGEWÖU cable is specially designed to provide medium voltage power while withstanding continuous motion, oil exposure, and harsh weather. Its flexibility and high resistance make it ideal for heavy-duty applications like harbor cranes and ship-to-shore cranes.
Q2: How does R-(N)TSCGEWÖU compare to other medium voltage cables?
Compared to stationary or standard medium voltage cables, R-(N)TSCGEWÖU cables are far more flexible, durable, and resistant to oils, making them better suited for moving equipment.
Q3: Is this cable suitable for outdoor and marine environments?
Yes, it’s designed as a weatherproof cable with high resistance to UV rays, oil, and corrosion, making it highly durable in outdoor and marine environments.

Why Buy from Us?
As a top medium voltage cable supplier, we understand the demands of industrial environments and offer the highest quality cables to meet your needs. Our medium voltage cable price structure is competitive, and we provide technical support for medium voltage cable installation to ensure optimal performance.
Whether you're looking to buy reeling drum cable, compare medium voltage cable vs low voltage cable, or are specifically interested in R-(N)TSCGEWÖU cable vs other cable types, our team can provide a solution tailored to your application.
The Type R-(N)TSCGEWÖU 3.6/6 to 18/30 kV Medium Voltage Reeling Drum Cable is a powerful, reliable, and highly flexible solution for port machinery. Built to endure constant movement, oil exposure, and weather, this flexible medium voltage cable is ideal for cranes, quayside equipment, offshore platforms, and more.

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.