Highlight: NGRDGCGOEU-J, Flexible Festoon Power Crane Cable, Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable
| Features: | Flexible, Oil and Sunlight Resistant | Uv Resistance: | Yes |
| Model: | (N)GRDGCGOEU-J | Application: | Crane Equipment |
| Place of Origin: | Hefei HONGKONG China | Brand Name: | ECKABEL™ |
| Certification: | DiN VDE 0295 Class 5 & DiN VDE 0207 | Model Number: | Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable Payment & Shipping Terms |
| Minimum Order Quantity: | 1000 Meter | Packaging Details: | Cable Reels or Packaging Bags |
| Delivery Time: | 15-30 Work Day | Payment Terms: | T/T, Western Union |
| Features: | Flexible, Oil And Sunlight Resistant | Product Type: | Electric Cable |
| Flexibility: | Flexible | Compact Installation: | Compact Design |
| Temperature Rating: | 90°C | Cable Type: | Power Cable |
| Maximum Ampacity: | 170 Amps | Safety Certifications: | Certified For Safety |
| Connector Type: | NEMA L5-30P | Conductor: | Finely stranded copper conductor (bare electrolytic copper), class 5 |
| Earth conductor: | Tinned, extremely finely stranded copper conductor, class FS | Insulation: | basic material EPR, rubber compound 3GI3 |
| Core identification: | black, blue, brown, earth conductor green-yellow | Core arrangement: | up to 10²mm: 4-core design from 16mm² on Three main conductors, earth conductor split into three parts and placed into the interstices |
| Inner sheath: | Basic material EPR, compound type GM1b, color: black | Overall shield: | Braid screen made of tinned copper wires, surface covered: >80%,transfer impedance <100mOhm/m at <= 30MHz |
| Outer sheath: | Basic material PCP, rubber compound 5GM3, color: black | Rated voltage: | Uo/U = 0.6/1 kV |
| Max. permissible operating voltage in AC systems: | U max (eff) = 1.2 kV | AC test voltage: | 5 kV, 5 min |
| max. permissible peak AC voltage: | U^= 2.4 kV | For connection on frequency converter: | U max = 690V |
| Current-carrying capacity: | According to DIN VDE 0298, Part 4 | Standards: | Based on DIN VDE 0250, Part 814 |
| -Fully flexible operation: | -35°C to +80°C | -Fixed installation: | -50°C to +80°C |
| The Max. permissible operating temperature of the conductor: | 90°C | Short-circuit temperature of the conductor: | 250°C |
| Tensile load: | Up to 15 N/mm² | Torsional stresses: | No application |
| Minimum bending radii: | According to DIN VDE 0298, Part 3 | Resistance to Oil: | DIN VDE 0473, Part 811-2-1, Para. 10 |
| Weather resistance: | Unrestricted use outdoors and indoors, resistant to ozone, UV, and moisture | No. of cores and nominal cross-section: | Shield cross-section |
| Conductor diameter: | Min.Overall diameter | Max. Overall diameter of the cable: | Approx. net weight for 1000 m |
| No*mm²: | mm² | mm: | mm |
| mm: | kg/km | 4×4: | 8 |
| 2.45: | 14.8 | 17.8: | 485 |
| 4×6: | 10.7 | 2.93: | 17.2 |
| 20.2: | 700 | 4×10: | 12.7 |
| 3.9: | 19.7 | 22.7: | 925 |
| 3×16+3×2.5: | 13.3 | 5.72: | 22.2 |
| 25.2: | 1150 | 3×25+3×4: | 15.9 |
| 6.75: | 25.3 | 28.3: | 1610 |
| 3×35+3×6: | 21.4 | 8.05: | 29.3 |
| 32.3: | 2160 | 3×50+3×10: | 24.9 |
| 9.6: | 35 | 38: | 3090 |
| 3×70+3×10: | 29.8 | 11.5: | 40.9 |
| 43.9: | 4100 | 3×95+3×16: | 36.9 |
| 14: | 44.2 | 47.2: | 5040 |
| 3X120+3X16: | 45.9 | 15.8: | 48.7 |
| 51.7: | 5900 | 3×150+3×25: | 53.3 |
| 17.8: | 55.1 | 58.1: | 7620 |
| No. of cores and nominal cross-section: | Conductor resistance | Inductance (core/core) at 10 kHz: | Capacitance (guidance value) at 1 kHz |
| Transfer impedance at 1 MHz: | Transfer impedance at 10 MHz | No*mm²: | Ohm/km |
| µH/km: | nF/km | mOhm/m: | mOhm/m |
| 4×4: | 4.95 | 550: | 180 |
| follows: | follows | 4×6: | 3.3 |
| 530: | 190 | 4×10: | 1.91 |
| 510: | 230 | 0.4: | 1.3 |
| 3×16+3×2,5: | 1.21 | 480: | 225 |
| 0.2: | 0.6 | 3×25+3×4: | 0.78 |
| 450: | 275 | 0.2: | 0.4 |
| 3×35+3×6: | 0.55 | 430: | 325 |
| 0.1: | 0.4 | 3×50+3×10: | 0.39 |
| 410: | 400 | 0.1: | 0.2 |
| 3×70+3×10: | 0.27 | 390: | 475 |
| 3×95+3×16: | 0.21 | 375: | 600 |
| 3X120+3X16: | 0.16 | 360: | 700 |
| 0.1: | 0.1 |
Payment & Shipping Terms
| Minimum Order Quantity: | 1000 Meter | Packaging Details: | Cable Reels or Packaging Bags |
| Delivery Time: | 15-30 Work Day | Payment Terms: | T/T, Western Union |
ECKABEL Cable Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable
Applications:
- Gantry Cranes
- Hall Gantry Cranes
- Rack Material Handling Equipment
- Transportation Systems
- Machine Tools
The ECKABEL Cable Type NGRDGCGOEU-J is a high-flexible festoon power crane cable designed for demanding industrial applications.
Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable FOR FC-DRIVES CONSTRUCTION
| Conductor | Finely stranded copper conductor (bare electrolytic copper), class 5 |
| Earth conductor | Tinned, extremely finely stranded copper conductor, class FS |
| Insulation | basic material EPR, rubber compound 3GI3 |
| Core identification | black, blue, brown, earth conductor green-yellow |
| Core arrangement | up to 10²mm: 4-core design from 16mm² on Three main conductors, earth conductor split into three parts and placed into the interstices |
| Inner sheath | Basic material EPR, compound type GM1b, color: black |
| Overall shield | Braid screen made of tinned copper wires, surface covered: >80%,transfer impedance <100mOhm/m at <= 30MHz |
| Outer sheath | Basic material PCP, rubber compound 5GM3, color: black |
Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable TECHNICAL DATA
| Rated voltage | Uo/U = 0.6/1 kV |
| Max. permissible operating voltage in AC systems | U max (eff) = 1.2 kV |
| AC test voltage | 5 kV, 5 min |
| max. permissible peak AC voltage | U^= 2.4 kV |
| For connection on frequency converter | U max = 690V |
| Current-carrying capacity | According to DIN VDE 0298, Part 4 |
| Standards | Based on DIN VDE 0250, Part 814 |
| Ambient temperature | |
| -Fully flexible operation | -35°C to +80°C |
| -Fixed installation | -50°C to +80°C |
| The Max. permissible operating temperature of the conductor | 90°C |
| Short-circuit temperature of the conductor | 250°C |
| Tensile load | Up to 15 N/mm² |
| Torsional stresses | No application |
| Minimum bending radii | According to DIN VDE 0298, Part 3 |
| Resistance to Oil: | DIN VDE 0473, Part 811-2-1, Para. 10 |
| Weather resistance: | Unrestricted use outdoors and indoors, resistant to ozone, UV, and moisture |
Type NGRDGCGOEU-J High Flexible Festoon Power Crane Cable SPECIFICATION
| No. of cores and nominal cross-section | Shield cross-section | Conductor diameter | Min.Overall diameter | Max. Overall diameter of the cable | Approx. net weight for 1000 m | Max. permissible tensile force |
| No*mm² | mm² | mm | mm | mm | kg/km | N |
| (N)GRDGCGOEU – J Festoon cables with overall screen | ||||||
| 4×4 | 8 | 2.45 | 14.8 | 17.8 | 485 | 240 |
| 4×6 | 10.7 | 2.93 | 17.2 | 20.2 | 700 | 300 |
| 4×10 | 12.7 | 3.9 | 19.7 | 22.7 | 925 | 600 |
| 3×16+3×2.5 | 13.3 | 5.72 | 22.2 | 25.2 | 1150 | 720 |
| 3×25+3×4 | 15.9 | 6.75 | 25.3 | 28.3 | 1610 | 1125 |
| 3×35+3×6 | 21.4 | 8.05 | 29.3 | 32.3 | 2160 | 1575 |
| 3×50+3×10 | 24.9 | 9.6 | 35 | 38 | 3090 | 2250 |
| 3×70+3×10 | 29.8 | 11.5 | 40.9 | 43.9 | 4100 | 3150 |
| 3×95+3×16 | 36.9 | 14 | 44.2 | 47.2 | 5040 | 4275 |
| 3X120+3X16 | 45.9 | 15.8 | 48.7 | 51.7 | 5900 | 5400 |
| 3×150+3×25 | 53.3 | 17.8 | 55.1 | 58.1 | 7620 | 6750 |
| No. of cores and nominal cross-section | Conductor resistance | Inductance (core/core) at 10 kHz | Capacitance (guidance value) at 1 kHz | Transfer impedance at 1 MHz | Transfer impedance at 10 MHz | Transfer impedance at 30 MHz |
| No*mm² | Ohm/km | µH/km | nF/km | mOhm/m | mOhm/m | mOhm/m |
| 4×4 | 4.95 | 550 | 180 | follows | follows | follows |
| 4×6 | 3.3 | 530 | 190 | follows | follows | follows |
| 4×10 | 1.91 | 510 | 230 | 0.4 | 1.3 | 3.5 |
| 3×16+3×2,5 | 1.21 | 480 | 225 | 0.2 | 0.6 | 1.5 |
| 3×25+3×4 | 0.78 | 450 | 275 | 0.2 | 0.4 | 1.3 |
| 3×35+3×6 | 0.55 | 430 | 325 | 0.1 | 0.4 | 0.9 |
| 3×50+3×10 | 0.39 | 410 | 400 | 0.1 | 0.2 | 0.7 |
| 3×70+3×10 | 0.27 | 390 | 475 | 0.1 | 0.2 | 0.5 |
| 3×95+3×16 | 0.21 | 375 | 600 | 0.1 | 0.2 | 0.4 |
| 3X120+3X16 | 0.16 | 360 | 700 | 0.1 | 0.1 |
0.3 |