ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments

Product Details

High quality ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
Mining Trailing Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: PROTOMONT NSSHOEU 3E, ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industri, 30kN Tensile Strength

Tensile Strength:30kNJacket:CPE Rubber
Weather Resistance:Resilient In Diverse WeatherOil Resistant:Yes
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 813Model Number:PROTOMONT NSSHOEU .../3E Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Features:Oil And Flame Resistant, UV ResistantChemical Stability:Stable In Chemical Environments
High Current Capability:Efficient High-current TransmissionCurrent Rating:1000A
Flexible:YesWaterproof:Suitable For Wet Conditions
Outdoor Suitability:Suited For Outdoor UseTailored For Handling:Enhances Material Handling Efficiency
Maximum Operating Voltage:2000VFlexible Handling:Easy Handling In Dynamic Conditions
Certification:RegionMA:China (Special Design)
MSHA P-189-3:United StatesBAS Fire Certificate:Bosnia-Herzegovina
TR-Certificate:Russian FederationGOST K:Kazakhstan
GOST B:BelarusParameter:Specification
Rated Voltage:0.6/1 kV (Alternative: 640/1140V)Max AC Operating Voltage:0.7/1.2 kV
Max DC Operating Voltage:0.9/1.8 kVAC Test Voltage:3 kV
Feature:MaterialInsulation:PROTOLON
Inner Sheath:Vulcanized RubberOuter Sheath:PROTOFIRM
Condition:Temperature RangeMaximum Conductor Temp.:90°C
Short Circuit Temp.:250°CFixed Installation:-40°C to +80°C
Flexible Operation:-25°C to +60°CFeature:Specification
Max Tensile Load:15 N/mm²Bending Radius:Meets DIN VDE 0298 Part 3 requirements

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments

Industrial applications demand rugged, reliable solutions, especially in high-stress settings like mining and tunnel construction.

The ECKABEL PROTOMONT NSSHOEU .../3E is engineered to withstand these challenges. With superior materials, innovative design, and a track record of performance, this cable delivers unmatched durability and efficiency in critical applications.

ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments 0

Product Overview

Key Identification

  • Brand: PROTOMONT
  • Type Designation: NSSHOEU .../3E
  • Voltage Rating: 0.6/1 kV
  • Standardization: Compliant with DIN VDE 0250-812

Primary Application Domains

This cable is built for environments where reliability is non-negotiable:

  • Underground mining installations
  • Tunnel construction projects
  • Open-cast mining operations
  • Quarry sites and similar industrial environments

​Power supply for:

Motors

Distribution boards

Semi-fixed installation systems

Certifications and Approvals

The PROTOMONT NSSHOEU .../3E is tested and approved by leading global standards:

Certification Region
MA China (Special Design)
MSHA P-189-3 United States
BAS Fire Certificate Bosnia-Herzegovina
TR-Certificate Russian Federation
GOST K Kazakhstan
GOST B Belarus

ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments 1

 

Technical Specifications

Electrical Characteristics

The electrical performance ensures operational safety and efficiency:

Parameter Specification
Rated Voltage 0.6/1 kV (Alternative: 640/1140V)
Max AC Operating Voltage 0.7/1.2 kV
Max DC Operating Voltage 0.9/1.8 kV
AC Test Voltage 3 kV

Conductor Engineering

  • Conductor Material: Untinned copper, finely stranded (Class 5)
  • PE-Conductor Configuration:
    • Individual-concentric or overall concentric spinning
    • Untinned copper wire arrangement

Core Characteristics

  • Core Count: Available in three, four, or five cores
  • Core Coloration: Black, Blue, Brown, Grey

Structural Composition

Insulation and Protective Features

Feature Material Compound Type
Insulation PROTOLON EPR-based (3GI3)
Inner Sheath Vulcanized Rubber GM1B
Outer Sheath PROTOFIRM Chlorinated Rubber (5GM5)

The outer sheath’s yellow color enhances visibility and safety.

Wire Spinning Technique

For enhanced mechanical durability, closed-lay spinning of steel/copper wires is used, along with vulcanized bonding between inner and outer sheaths.


Performance Capabilities

Thermal Resistance

The cable is designed to perform under extreme temperatures:

Condition Temperature Range
Maximum Conductor Temp. 90°C
Short Circuit Temp. 250°C
Fixed Installation -40°C to +80°C
Flexible Operation -25°C to +60°C

Environmental Resilience

The PROTOMONT NSSHOEU .../3E offers:

  • Fire Resistance:
    • Compliant with EN 60332-1-2 and IEC 60332-1-2
  • Oil Resistance:
    • Tested to EN 60811-404 and IEC 60811-404
  • Weather Resistance:
    • Fully resistant to ozone, moisture, and extreme conditions

Mechanical Characteristics

Structural Durability

Feature Specification
Max Tensile Load 15 N/mm²
Bending Radius Meets DIN VDE 0298 Part 3 requirements

Professional Considerations and Application Guidance

Critical Selection Criteria

Choosing the right cable is critical. When selecting the PROTOMONT NSSHOEU .../3E, ensure:

Compatibility with specific industrial equipment

Consideration of environmental challenges, such as moisture or heat

Adherence to proper installation procedures as per manufacturer guidelines

Regular inspections to ensure long-term safety and performance


ECKABEL PROTOMONT NSSHOEU .../3E: Robust Cable Solution for Challenging Industrial Environments 3

 

Potential Application Challenges

The PROTOMONT NSSHOEU .../3E overcomes common challenges such as:

  • Mechanical stress: The durable design resists wear and tear from movement.
  • Electrical stability: Advanced insulation ensures consistent performance.
  • Thermal variations: Designed to handle fluctuating underground temperatures.
  • Premature degradation: Robust materials extend operational life.

Compliance and Quality Assurance

This cable undergoes rigorous testing, earning certifications that meet international standards. It is engineered for reliability, even in the most demanding environments. ECKABEL’s strict quality assurance guarantees:

  • High performance
  • Consistent safety
  • Comprehensive documentation for traceability

Conclusion

The ECKABEL PROTOMONT NSSHOEU .../3E is more than just a cable—it’s a dependable partner in industrial operations.

Whether it’s mining, tunnel construction, or heavy-duty industrial use, this cable delivers superior performance, safety, and durability.


Recommended Next Steps

  • Consult ECKABEL’s technical support for tailored advice.
  • Request a detailed datasheet for full specifications.
  • Conduct a compatibility assessment for your site-specific needs.

For the ultimate in industrial cable solutions, trust ECKABEL PROTOMONT NSSHOEU .../3E. It’s the reliable choice for challenging environments.


Important Note: Always involve a qualified electrical engineer during the selection and installation process to ensure compliance with your application’s requirements.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.