ECKABEL (HongKong) Special Cable Co.,Ltd Email: sales@eckabel.com

Products

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications

Product Details

High quality ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications from China, China

Place of Origin:
HONGKONG China
Brand Name:
ECKABEL Cable
Certification:
CSA & MSHA
Model Number:
Mining Trailing Cable

Payment & Shipping Terms

Minimum Order Quantity:
200 M
Price:
Contact us for specifications
Packaging Details:
Cable Reels or Packaging Bags
Delivery Time:
15-30 Days
Payment Terms:
T/T or Western Union

Highlight: PROTOMONT EMV-FC, ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Indust, Copper Conductor Material

Conductor Material:CopperArmor Material:Galvanized steel wire braid
Voltage:Medium VoltagePackage:Wooden Drum
Place of Origin:Hefei HONGKONG ChinaBrand Name:ECKABEL™
Certification:VDE 0250 Part 813Model Number:PROTOMONT EMV-FC Payment & Shipping Terms
Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union
Armor Material:Galvanized Steel Wire BraidTensile Strength:30kN
Current Rating:1000AImpact Resistant:Guards Against Impact Damage
Material:Special CompoundsHighly Reliable:Trustworthy In Critical Tasks
Custom Power Solutions:Tailored For Equipment NeedsEfficient Extraction:Aids Mineral Extraction Efficiency
Chemical Resilience:Withstands Various Mining ChemicalsMaximum Tension:7500 Lbs
Shielding Coverage:100%Parameter:Specification
Rated Voltage:Uo/U = 0.6/1 kV (640/1140V compatible)Maximum AC Operating Voltage:0.7/1.2 kV
Maximum DC Operating Voltage:0.9/1.8 kVAC Test Voltage:5 kV
Feature:DetailsMaterial:Finely stranded, tinned copper
Classification:Class 5 conductor (DIN VDE 0295)Tensile Load Capacity:Up to 15 N/mm²
Torsional Stress Tolerance:25° per meterComponent:Material
Compound Type:Key FeatureCore Insulation:PROTOLON (EPR)
3GI3:High thermal resistanceInner Sheath:Vulcanized rubber (EPR)
GM1B:Enhanced flexibilityOuter Sheath:PROTOFIRM synthetic elastomer
CR:Exceptional weather resistanceOuter Sheath Color:Distinctive yellow
Condition:Temperature RangeMaximum Conductor Temperature:90°C
Short Circuit Temperature:250°CFixed Installation Range:-40°C to +80°C
Fully Flexible Operation Range:-25°C to +60°CApplication:Depth
Wastewater Systems:Up to 10mFresh and Saltwater Systems:Up to 500m
Minimum Bending Radius:As per DIN VDE 0298 part 3Flexibility:Suitable for continuous movement scenarios

Payment & Shipping Terms

Minimum Order Quantity:800 MeterPackaging Details:Cable Reels or Packaging Bags
Delivery Time:15-30 Work DayPayment Terms:T/T, Western Union

PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications

Industrial operations today require cables that can withstand extreme conditions while delivering optimal performance.

The PROTOMONT EMV-FC cable, designated as (N)SSHCOEU, is a cutting-edge solution for frequency converter-controlled systems operating in challenging environments.

Engineered for reliability, durability, and advanced electromagnetic compatibility (EMC), this cable excels in mining, construction, marine, and other demanding industrial settings.


Product Overview

The PROTOMONT EMV-FC is specifically designed to address the challenges of power transmission in environments where both mechanical and electrical stress are significant.

Its robust construction and high-quality materials make it ideal for continuous movement applications and operations in water, ensuring seamless power delivery under the harshest conditions.

Key Application Domains

This versatile cable caters to several critical industrial needs, including:

  • Mining Industry: Powering machinery and equipment in underground and surface mining.
  • Construction Sites: Providing reliable connections for mobile equipment and heavy-duty tools.
  • Marine and Offshore Applications: Suitable for installations in fresh and saltwater environments.
  • Material Handling Equipment: Ensures smooth operation for cranes, conveyor systems, and loaders.
  • Wastewater Systems: Reliable under submersion conditions up to 10m and in more extreme depths for specific applications.

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications 1

 

Technical Specifications

Electrical Characteristics

Parameter Specification
Rated Voltage Uo/U = 0.6/1 kV (640/1140V compatible)
Maximum AC Operating Voltage 0.7/1.2 kV
Maximum DC Operating Voltage 0.9/1.8 kV
AC Test Voltage 5 kV

These specifications ensure stability under varying loads, making the cable suitable for high-demand industrial applications.


Mechanical Design

Conductor Specification

Feature Details
Material Finely stranded, tinned copper
Classification Class 5 conductor (DIN VDE 0295)
Tensile Load Capacity Up to 15 N/mm²
Torsional Stress Tolerance 25° per meter

The finely stranded tinned copper conductor offers flexibility and enhanced resistance to corrosion, crucial for long-term reliability in harsh environments.

Insulation and Sheathing

Component Material Compound Type Key Feature
Core Insulation PROTOLON (EPR) 3GI3 High thermal resistance
Inner Sheath Vulcanized rubber (EPR) GM1B Enhanced flexibility
Outer Sheath PROTOFIRM synthetic elastomer CR Exceptional weather resistance
Outer Sheath Color Distinctive yellow   Easy identification

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications 2

 

Thermal Performance

Condition Temperature Range
Maximum Conductor Temperature 90°C
Short Circuit Temperature 250°C
Fixed Installation Range -40°C to +80°C
Fully Flexible Operation Range -25°C to +60°C

The wide operating temperature range makes this cable ideal for environments subject to extreme thermal fluctuations.


Advanced Protection Features

The PROTOMONT EMV-FC is engineered to offer comprehensive protection against environmental and mechanical threats:

Environmental Resistance

  • Fire Resistance: Complies with EN 60332-1-2 and IEC 60332-1-2, ensuring safety in critical situations.
  • Oil Resistance: Certified to EN 60811-404 and IEC 60811-404, ensuring durability in oil-rich environments.
  • Ozone and Moisture Resistance: Ensures long-term reliability indoors and outdoors.

Electromagnetic Compatibility (EMC)

  • Features an optimized concentric braid of tinned copper wires for superior EMC performance, making it suitable for applications sensitive to electrical interference.

 

Unique Installation Characteristics

The cable’s design ensures flexibility and resilience, meeting the demands of dynamic and stationary installations alike.

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications 3

Water Deployment Capabilities

Application Depth Temperature
Wastewater Systems Up to 10m 40°C
Fresh and Saltwater Systems Up to 500m Varies

These features make it a reliable choice for underwater installations and wastewater management.

Bending and Installation Guidelines

Parameter Specification
Minimum Bending Radius As per DIN VDE 0298 part 3
Flexibility Suitable for continuous movement scenarios

Recommended Applications

This cable is particularly suited for:

  • Frequency Converter Systems: Delivering stable power for precision-driven operations.
  • Marine Equipment: Withstanding corrosion and water pressure in offshore installations.
  • Mining Machinery: Resilient against mechanical stress and harsh environmental factors.
  • Mobile Construction Equipment: Supporting dynamic operations with unmatched flexibility.

Technical Considerations for Engineers

Selection Criteria

When specifying the PROTOMONT EMV-FC, engineers should assess:

  • Environmental factors such as temperature and exposure to chemicals or oils.
  • The level of electromagnetic interference (EMI) present in the operational area.
  • Load requirements, including torsional and tensile stress tolerances.

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications 4

Performance Optimization

To ensure long-term reliability:

  • Regularly inspect cables for wear and damage.
  • Follow manufacturer-recommended installation and routing practices.
  • Use cable supports and guides to minimize stress during operation.

ECKABEL PROTOMONT EMV-FC: Advanced Frequency Converter Cables for Extreme Industrial Applications 5

 

Certification and Compliance

The cable meets international standards, offering reliability and peace of mind in diverse operational settings. Certifications include:

  • MSHA P-189-3 Approval for mining applications.
  • Russian Federation Fire Certificate and GOST K/B compliance for industrial safety.
  • TR-Certification for robust global usability.

Conclusion

The PROTOMONT EMV-FC cable is a game-changer in power transmission, delivering unmatched reliability, flexibility, and durability. Its advanced design addresses the challenges of frequency converter systems in extreme industrial environments, ensuring optimal performance and safety.

Recommended Next Steps

  • Consult PROTOMONT technical support for tailored application advice.
  • Request a comprehensive technical datasheet for detailed specifications.
  • Partner with a certified electrical engineer for professional installation guidance.

The PROTOMONT EMV-FC cable stands as a reliable partner for industries demanding high-performance solutions, proving that quality and innovation can coexist seamlessly.

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.

Inquiry

Need Pricing Or Datasheet?

Send voltage, conductor size, cable length and application environment for a faster recommendation.

Request Quote